zotero-db/storage/4LMKBZHY/.zotero-ft-cache

385 lines
21 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

Eur. Phys. J. C (2018) 78:607 https://doi.org/10.1140/epjc/s10052-018-6080-x
Regular Article - Experimental Physics
The light speed versus the observer: the KennedyThorndike test from GRAAL-ESRF
V. G. Gurzadyan1,2,a, A. T. Margaryan3
1 Center for Cosmology and Astrophysics, Alikhanian National Laboratory and Yerevan State University, Yerevan, Armenia 2 SIA, Sapienza Universita di Roma, Rome, Italy 3 Department of Experimental Physics, Alikhanian National Laboratory, Yerevan, Armenia
Received: 14 April 2018 / Accepted: 16 July 2018 / Published online: 30 July 2018 © The Author(s) 2018
Abstract High precision tests of the light speed constancy for all observers as a empirical basis of Special Relativity have continuously been among the goals of advanced experimental studies. Based on the Compton edge method proposed by us (Gurzadyan and Margarian in Phys Scr 53:513, 1996), a constraint on the one-way light speed isotropy and Lorentz invariance violation has been obtained at the dedicated GRAAL experiment at European Synchrotron Radiation Facility (ESRF, Grenoble) (Gurzadyan et al. in Mod Phys Lett A 20:1, 2005, Nuovo Cimento 122:515, 2007, Proceedings of the XII M. Grossmann meeting on general relativity, vol B. World Scientific, p 1495. arXiv:1004.2867, 2012; Bocquet et al. in Phys Rev Lett 104:241601, 2010). Using the GRAAL data we now get a new constraint on one of the key tests of Special Relativity—the KennedyThorndike experiment (Kennedy and Thorndike in Phys Rev 42:400, 1932) in probing light speed invariance with respect to the velocity of the observer (apparatus). Our analysis takes advantage of GRAALs setup where two separate energy scales are involved: first, via the position of the Compton edge determining the light speed in the reference frame of incident 6 GeV electrons within the tagging system, second, in the calorimeter via the 1.27 MeV photons of the 22Na source. The two energy scales are engaged to each other through production of η mesons by tagged laser Compton backscattered γ -rays. The accuracy of the calibration and stability of energies reached in each section enable us to obtain the limit of 7 × 1012 for the KennedyThorndike test, which improves the currently existing limits by three orders of magnitude.
Introduction
The light speed constancy for all observers and the equivalence principle are the key empirical bases of Einsteins
a e-mail: gurzadyan@yerphi.am
Special and General Theories of Relativity. Long after the creation of the theories of relativity Einstein remained attentive to the ongoing experiments on the empirical bases [1]. The observational evidence for the existence of dark energy and dark matter have increased the interest in models with varying light speed and Lorentz invariance violation (LIV) and hence in the relevant experimental activity. Particularly, the tests of the light speed invariance with respect to the direction (isotropy) and the LIV models have always been among the goals of high precision experiments [24]. Their link to General Relativity and gravitational waves gained further interest upon the LIGO-Virgos detection of gravitation waves [5], while recent satellite studies enable one to improve the equivalence principle precision limits.
Three types of light speed involving experiments have been considered of particular interest (see [6] and the references therein); although each measuring a particular effect, they are mutually complementary in probing Special Relativity:
(a) Light speed isotropy, i.e. invariance to the direction (MichelsonMorley (MM) test);
(b) Light speed independence on the velocity of the observer (KennedyThorndike (KT) test) [7];
(c) Time dilation (Ives and Stilwell (IS) test).
Among the experiments on the MM-test there were the measurements based on the idea of the daily monitoring of the Compton Edge (CE), which corresponds to the maximal energy of the scattered photons (see below), with respect to the frame of the cosmic microwave background (CMB) as suggested in [8]. That idea has been realized at the GRAAL experiment of the European Synchrotron Radiation Facility (ESRF, Grenoble) at the scattering of accelerated electrons of 6.03 GeV energy and laser monochromatic photons. The results of those studies enabled one to constrain the one-way
123
607 Page 2 of 6
Eur. Phys. J. C (2018) 78:607
light speed isotropy to the precision of 1014 (MM-test) [9 12].
Here we use the data of the GRAAL experiment to obtain a constraint also for the other key test, namely, the Kennedy Thorndike one [7]. The current KT-test precision is 107 108 [13,14]; for details and references we refer to the reviews of Refs. [2,3,6]. Among the proposed KT-tests is a dedicated satellite experiment [15].
More specifically, to probe the light speed invariance with respect to the velocity of the apparatus, namely, with respect to the beam electron reference system and the reference system of the calorimeter, we use the data of GRAALs Laser Compton Backscattered (LCB) experiment, the energy calibration accuracy and stability of the Compton edge obtained in the tagging system and of the η-meson production detected in the BGO electromagnetic calorimeter [16,17].
Three issues make the use of the GRAAL data for the KT-test efficient:
(a) the γ 2-dependence (γ is the Lorentz factor) of energy of the Compton edge;
(b) the calibration of the absolute energy scale of the internal tagging system by CE;
(c) the calibration of the absolute energy scale of the electromagnetic calorimeter using the 1.27 MeV photons from 22Na source.
In the analysis below we obtain the accuracy of the invariance of the speed of light via its evaluation, first, with respect to the frame of the incident electron undergoing the Compton scattering, second, with respect to the laboratory frame in the calorimeter. We obtain the limit 7.1 × 1012 for the KT-test—on the light speed invariance with respect to the velocity of the apparatus—which is better than the existing limits by 3 orders of magnitude.
and β = v/c, v is the electron velocity.
From Eq. (1) the maximum energy of the scattered photons obtained in the small angle limit, θγ → 0, called the Compton edge, and for a head-on collision, θ0, θ = π , is found to be
ωCE
=
(1 + β)2γ 2ω0
1
+
2(1+β)γ ω0 mc2
,
(3)
where m is the electron mass. When the electron beam energy is kept stable to high accu-
racy, then from Eq. (2)
βdβ
=
1 γ2
dγ γ
.
(4)
The Compton scattering of laser photons of energy ω0 and high energy electrons with Lorentz factor γ can be represented as a four step process, if one accepts the possibility of non-constancy of the light speed:
1. In the laboratory frame the photons of energy ω0 travel at speed c1 (allowing speed anisotropy); the electrons possess energies E1 and velocity v.
2. In the rest frame of the initial electrons the Doppler
shifted photons (due to relativistic time dilation) of
energy
ω01 = γ2(1 β2 cos θ )ω0
(5)
scatter over electrons at velocity c2 (allowing for a possible velocity dependence in the frame of the electron),
where β2 = v/c2. In the case of head-on collisions, θ = π and ωe1 = γ2(1 + β2)ω0. 3. In the rest frame of an electron, 180◦ Compton scattered
photons of energies
1 Compton edge
The kinematics of the Compton scattering defines the energy ωs of photons having scattered off the electrons of energy Ee in dependence on the energy of the primary photon ω0 as follows (e.g. [8]):
ωs
=
1
β
(1 cos θγ
β cos θ )ω0
,
+ (1 cos θ0)(ω0/Ee)
(1)
where θ0 is the angle between incident and scattered photons momenta, and θ , θγ are the angles between the momentum of electron and the incident and the scattered photons, respec-
tively. The Lorentz factor of the electron in the laboratory
frame is
γ = (1 β2)1/2,
(2)
ω02 = ωe1/(1 + 2ωe1/mc2)
(6)
move away at velocity c3 (due to the photon direction change by 180◦). The recoil electrons have equal and
opposite momenta.
4. Finally, in the laboratory frame we have the Compton
scattered and Doppler shifted laser photons of energies
ω21 = γ4(1 + β4cosθγ )ω02
(7)
and velocity c4 (allowing for direction dependence), where β4 = v/c4, γ4 = (1 β42)1/2, and we have recoil electrons of energies E2 = E1 ω21. In our case
θγ = 0 and θ0, θ = π , and for CE we have
123
Eur. Phys. J. C (2018) 78:607
Page 3 of 6 607
ω2m1ax = γ4(1 + β4)ω02 = γ2γ4(1 + β4)(1 + β2)ω01/(1 + 2γ4(1 + β4)ω01/mc2)
(8)
and
E2min = E1 ω2m1ax.
(9)
In Special Relativity, obviously, ci = c, βi = β, γi = γ , whence ω2m1ax in Eq. (9) coincides with ωCE in Eq. (3), thus confirming that we deal with the light speed in the initial
electrons frame.
2 The Compton edge at GRAAL: the light speed in the moving electrons frame
The GRAAL facility, installed in ESRF, involves a γ -ray beam originating with Compton scattering of 514 and 351 nm laser photons and 6.03 GeV electrons, accelerated in the storage ring [1618]. The incident photons were produced by a high-power Ar laser located about 40 m from the intersection location in the tagging box. The laser beam entered the vacuum region through a MgF window and then, by the Alcoated Be mirror, was directed toward the electron beam. The laser photon and electron beams overlapped within a 6.5 m long section. Then the scattered photons were absorbed within a four-quadrant calorimeter, which enabled one to stabilize the center of the laser beam within 0.1 mm. The scattered electrons were extracted from the main beam by means of a magnetic dipole located after the straight section.
The position of the electron beam could then be accurately measured within the tagging system located 50 cm from the exit of the dipole. The tagging system played the role of a magnetic spectrometer which enabled one to extract the information on the scattered electron (photon) momenta. The tagging system included a position-sensitive Si µ-strip detector of 128 strips of 300 µm pitch and 500 µm thickness each, linked to a set of fast plastic scintillators for the timing information and triggering the data acquisition. The detectors were located in a movable box shielded for a strong X-ray background generated in the dipole. The X-ray background led to remarkable heat release, which led to temperature variations inside the tagging box correlated with the ESRF beam intensity. This effect was controlled and corrected.
Equation (3) for the CE in the case of the GRAAL setup has the form (see [9])
ωCE
=
γ me XCE , A + XCE
(10)
where A is a constant, and XCE is the distance of the scattered electrons position in the tagging detector from the initial beam.
Then from Eqs. (3) to (10) one has
X CE
=
4γ Aω0 m
(11)
and hence
δ XCE = δγ + δ A + δω0 .
(12)
XCE γ A ω0
Then, as follows from Eqs. (4), (10)(12), the position of the CE defines the light speed variation [8,9]
δc = γ 2 δ XCE .
(13)
c
X CE
Figure 1 exhibits the GRAALs CE data (2075 points) vs. the 24 h period; the vertical axis is XCE in GRAALs microstrip scale units. The MM-test was obtained via such a monitoring for daily variations of the CE; for details see [9,11]. For the MM-test the stability of the beam energy and tagging system was crucial, while the stability of the thermal expansion of the tagging system was subject of a separate study (for details see [11] and the discussion in [19]). That resulted in a relative CE accuracy and enabled one to constrain the light speed direction-dependence precision for the Lorentz factor of the ESRF electron beam γ = 11,820 to an accuracy of [11,12]
δc(θ )/c 1014.
(14)
For the KT-test, however, not of a relative but of an absolute value of the energy scales the precision is needed, which, as we show below, is also possible both due to the experimental setup of the GRAAL facility and the high stability of the relevant parameters.
The CE method, i.e. the precise evaluation of CE position (Fig. 2) has been efficiently used at GRAAL experiment in order to calibrate the tagging system. Namely, the CE has been localized at precision about 10 µm of the 128-strip tagging box which corresponded to [17]
ΔEγ 2 × 104.
(15)
Eγ
The stability and high resolution of the accelerator electron beam and GRAALs tagging system allow one to achieve the accuracy for the light speed isotropy limit 1014. In this way the energy scale of the tagging system is determined by the light speed in the incident electrons frame.
3 The BGO calorimeter: the light speed in the laboratory frame
A high resolution and large solid angle BGO electromagnetic calorimeter combined with multiwire proportional chambers
123
607 Page 4 of 6
Eur. Phys. J. C (2018) 78:607
Fig. 1 GRAAL data: CE vs. 24-h period; red vertical lines denote the beam refill instances [9,11]
Fig. 2 The Compton edge for the green laser line (2.41 eV) observed at the GRAAL facility; the counts vs. the microstrip detector scale. Details are in [9]
and scintillator counters was another essential section of the GRAAL facility [16]. A calorimeter made of 480 crystals each of 21 radiation lengths was used for detection of γ photons coming e.g. from η → 2γ decay. The crystals were
distributed within clusters and the photon energy resolution was about 3%. For 3 cm target the angular resolution yielded 6◦ and 7◦ for polar and azimuthal angles, respectively.
The absolute calibration of crystals and its monitoring has been performed using the 1.27 MeV photons from a 22Na source and via creation of a special monitoring system [16,17]. The nonlinearity of this setup, which included the electronics and BGO detectors, is on the level of 103. Thus, in this approach involving 22Na the energy scale of the BGO calorimeter is determined by the light speed in the laboratory frame.
The recoil proton track is measured by a set of Multi-Wire Proportional Chambers (MWPCs) with the average polar and azimuthal resolutions of 1.5◦ and 2◦, respectively, for the forward angle tracks. For the charged particles emitted in the forward direction, a Time-of-Flight (ToF) measurement is provided by a double scintillator telescope placed at a distance of 3 m from the target and having a resolution of 600 ps, the calibration of which was obtained from fast electrons produced in the target.
The GRAAL experiment has traced the reaction γ + p → η + p. Only events with two neutral clusters in the BGO calorimeter and a single charged particle track were selected. Channel selection was achieved by applying the following
123
Eur. Phys. J. C (2018) 78:607
Page 5 of 6 607
Fig. 3 a Invariant mass spectrum for η → 2γ and b missing mass spectrum calculated from the proton momentum, the data (dots) from [17]. The best fit curves for both data are shown; the axes denote the counts (in arbitrary units) vs. the mass scale (in GeV/c2)
cuts on the invariant mass of detected photons (M2g); the
energy of η mesons (Rη = Eη/Eη); the direction of pro-
tons
(dθ p
=
θ
p
θp,
dφ p
=
φ
p
φ p );
the
energy
of
pro-
tons (dtp = ToFp ToF p), where “*” denotes the variables
calculated from the two-body kinematics as opposed to the
measured ones; for details see [17]. The applied cuts and
two-body kinematics directly relate the invariant and missing
masses of the η-mesons to the energies of incoming photons.
In Fig. 3a, b two examples of experimental distributions
[17] with the invariant mass of the η and the missing mass
calculated from the recoil proton momentum along with their
fits are given. We have computed the 9th order polynomial
fit for both data in Fig. 3a, b. The results in Fig. 3a determine
the mean value of the invariant mass of the η meson as mη = 548.46 MeV with a standard error of 0.05 MeV for about 106
events; the computed mean value differs from its PDG value
m
a η
=
547.862
±
0.17
MeV
[20]
as
548.46 547.86
=
0.6 i.e. to an accuracy 1.1 × 103. For Fig. 3b we similarly
obtain the η missing mass mη = 552.16 with standard error
0.058, which differs from the PDG value, 552.16547.86 = 4.3, i.e. to an accuracy 7.8 × 103. This poorer precision is
obviously due to the ToF system calibration, which is used
for a determination of the proton momentum. It is worthy to
mention that the data obtained without CE calibration of the
internal tagging system define the η meson invariant mass as 542.8 MeV, i.e. to the lower accuracy of 102 [16].
idea is the following. Two processes can be distinguished at the GRAAL experiment which, respectively, define two energy scales for photons, i.e. of the LCB γ -rays and of the BGO calorimeter. The first one is the CE position, which is determined by the light speed in the moving electrons frame, the second one is the BGO calorimeter energy scale determined by the 1.27 MeV photons of 22Na.
The two separate energy scales of the GRAAL experiment are linked to each other through the η-meson production process by Compton backscattered photons. Then, from the accuracy of the measured η-meson invariant mass, i.e. from the fit of the data in Fig. 3a, we have
dγ γ
=
maη mη
≤ 1.1 × 103.
(16)
It is remarkable that this accuracy is reached from the
energy calibration using the CE position with a precision about 10 µm or ΔEγ /Eγ 2 × 104 [17] and taking into account nonlinearities of the BGO calorimeter on the level of 103 [16]: the energy calibration of the tagged system
is extracted run by run from the fit of the CE position with
that precision. From this, in view of Eqs. (13) and (16), we
arrive at the light speed constancy in the incident accelerator
electrons frame to accuracy
δc(v)/c = 7.1 × 1012.
(17)
4 The KT-test at GRAAL
We are interested in the use of the above-mentioned results of the GRAAL experiment for the KT test (see also [19]). The
This defines the precision of the KT-test of the light speeds invariance with respect to the velocity v of the observers frame, i.e., of the electron of that velocity vs. the laboratory one.
123
607 Page 6 of 6
Eur. Phys. J. C (2018) 78:607
5 Conclusions
References
The KennedyThorndike experiment is concerned with one of the main tests for Special Relativity and Lorentz invariance. That test concerns the light speed invariance with respect to the velocity of the inertial frame of the observer. The CE data of the GRAAL-ESRF experiment which previously have been efficiently used for MichelsonMorley-like test, i.e. for probing the direction-dependence of the light speed via monitoring of the stability of CE, are now shown to be informative also for the KT-test. In the analysis performed the invariance of the light speed is tested with respect to the accelerated 6 GeV electrons frame and with respect to the laboratorys one. The obtained accuracy is better than the existing KT-limits by three orders of magnitude and yields 7.1 1012.
This confirms the power of the Compton edge method for revealing information on the basic physics in accelerator experiments, as well as the advanced parameters reached at ESRF and GRAALs experimental setup.
Acknowledgements We are thankful to J.-P. Bocquet, C. Schaerf, and D. Rebreyend of the GRAAL collaboration and to A. Kashin for numerous discussions.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecomm ons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Funded by SCOAP3.
1. A. Einstein, Forsch Und Fortschritte 3, 36 (1927) 2. D. Mattingly, Living Rev. Relativ. 8, 5 (2005) 3. V.A. Kostelecky, N. Russell, Rev. Mod. Phys. 83, 11 (2011) 4. D. Colladay. arXiv:1706.06637 5. I.M. Shoemaker, K. Murase. arXiv:1710.06427 6. C. Lammerzahl et al., Int. J. Mod. Phys. D. 11, 1109 (2002) 7. R.J. Kennedy, E.M. Thorndike, Phys. Rev. 42, 400 (1932) 8. V.G. Gurzadyan, A.T. Margarian, Phys. Scr. 53, 513 (1996) 9. V.G. Gurzadyan et al., Mod. Phys. Lett. A 20, 1 (2005) 10. V.G. Gurzadyan et al., Nuovo Cimento 122, 515 (2007) 11. J.-P. Bocquet et al., Phys. Rev. Lett 104, 241601 (2010) 12. V.G. Gurzadyan et al., in Proceedings of the XII M. Grossmann
Meeting on General Relativity, vol. B, (World Scientific, 2012), p. 1495. arXiv:1004.2867 13. P. Wolf et al., Gen. Relativ. Gravit. 36, 2351 (2004) 14. M.E. Tobar et al., Phys. Rev. D. 81, 022003 (2010) 15. J. A. Lipa et al., (2012). arXiv:1203.3914 16. F. Ghio et al., Nucl. Instr. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 404, 71 (1998) 17. O. Bartalini et al., Eur. Phys. J. A 33, 169 (2007) 18. J.P. Bocquet et al., Nucl. Phys. A 622, 125 (1997) 19. V. Gurzadyan et al., Compton Edge probing basic physics at Jefferson Laboratory: light speed isotropy and Lorentz invariance, proposal for JLab PAC (2017). arXiv:1706.08907 20. C. Patrignani et al. (Particle Data Group), Chin. Phys. C 40, 100001 (2017)
123