zotero-db/storage/5GAVDTXN/.zotero-ft-cache

1854 lines
124 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

Accepted Manuscript
Title: Theory, Technology and Applications of Piezoresistive Sensors: a Review
Authors: A.S. Fiorillo, C.D. Critello, A.S. Pullano
PII: DOI: Reference:
S0924-4247(18)30843-4 https://doi.org/10.1016/j.sna.2018.07.006 SNA 10871
To appear in:
Received date: Revised date: Accepted date:
Sensors and Actuators A
22-5-2018 27-6-2018 2-7-2018
Please cite this article as: Fiorillo AS, Critello CD, Pullano AS, Theory, Technology and Applications of Piezoresistive Sensors: a Review, Sensors and Actuators: A. Physical (2018), https://doi.org/10.1016/j.sna.2018.07.006
This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
1
Review Article Theory, Technology and Applications of Piezoresistive Sensors: a Review
A.S. Fiorilloa*, C.D. Critelloa§, A.S. Pullanoa§
IPT aDepartment of Health Sciences, University Magna Graecia of Catanzaro, Catanzaro, Italy R * Corresponding Author: C Prof. Antonino S. Fiorillo S nino@unicz.it ANU §Contributed equally to the manuscript
Abstract
M
Sensors based on the detection of small resistance variations are universally recognized as
D piezoresistive. Being one of the simplest, most common and most investigated classes of E sensors, continuous efforts are focused on creating improved devices with higher T performance that can be used in many commercial and noncommercial applications (e.g. P evaluation of strain, pressure, acceleration, force etc.). Consequently, despite the fact that E more than 150 years have passed since the discovery of the piezoresistive effect in some C classes of metals and semiconductors, the development of such sensors remains interesting Cand topical. Moreover, with the advent of secondgeneration robotics, research on Apiezoresistive sensors has undergone a massive increase. This paper aims to be a short,
selfconsistent vademecum which would be useful to researchers and engineers, since it
focuses on the fundamentals of theory, materials, and readoutcircuit design pertinent to
the most recent developments in the field of piezoresistive sensors.
2
Abbreviations
A
Area
a
Lattice constant
ACM
Common mode gain
Ad B CMRR D E Ԑ F GF h I
k l L m m* n p q
Differential gain Conductivity factor Common Mode Rejection Ratio
T Beam length P Energy I Electric field
Force
R Gauge factor
Planck's constant
C Inertia S Electric current
Wavenumber
U Length
Quantum well width
N Mass
Effective mass
A Principal quantum number
Particle momentum
M Electron charge
R s T
D t' E U
V
T v P W
X
E 
αi, βi, γi
C δ
ε
Cη Aϑ
Electric resistance Stress Temperature Scattering mean time Potential energy Volume velocity Width Volume fraction Temperature coefficient Direction cosines Displacement Strain Elasticity Resistance variation
μ
Charge mobility
Poissons ratio
πij
Piezoresistive coefficient

Resistivity
σ
Conductivity
σl, σt
Longitudinal, Transverse stress
3
τ
Torque
Ψ
Wave function
ψn
Timeindependent wave function
Angular velocity
Keywords
Piezoresistance; piezoresistive devices; sensors; strain; pressure gauges; metals; semiconductors; polymers; micromachining; electronic circuits; thick film sensors; thin
T film sensors; tactile sensors. RIP 1. Introduction
C Piezoresistive sensors base their operating principle on the piezoresistive effect S experienced by some classes of materials upon elastic deformation. Universally recognized U as the most widelyused devices on both micro (integrated devices, N microelectromechanical systems “MEMS”, etc.), and macroscales (e.g. single sensors, A arrays of sensors) their scientific interest is attested to by the increasing number of scientific M publications involving piezoresistivity, the trend of which is shown in Fig.1. A more
comprehensive analysis of the literature shows that piezoresistive sensors, even those embedded in sophisticated electronic devices, have been very pervasive in different fields
D (e.g. biological and biomedical applications, harsh environments, heavy industry). E The application of piezoresistive sensors has progressed enormously in the wellknown T field of robotics in its more general sense, as will be emphasized in this review [1, 2]. In P the latest literature, many efforts have been focused on the integration of such sensors in
biomedical robotics for tactile perception and for the development of the socalled
E “electronic skin” (eskin) [3, 4] in addition to grasping [5, 6], and use in exoskeletons and C artificial limbs [7]. Nevertheless, in the field of advanced robotic tactile sensors Cpiezoresistive materials have been in constant competition with piezoelectric materials Asince the 80s [3, 4, 8, 9].
This paper is organized with the first part focused on the background of piezoresistivity in metals and semiconductors in order to highlight the different origins of the piezoresistive effect. Then a section follows which is dedicated to the transducers based on both the geometrical and the physical piezoresistive effect with particular emphasis on the adopted
4
materials, technological solutions, and applications. Finally, a section is dedicated to the most recent advances in the design of the readout of electronic circuits.
2. Piezoresistivity
The discovery of piezoresistivity dates back to 1856, and is attributed to Lord Kelvin (Sir William Thomson, Belfast, 18241907) [10, 11]. A step forward in the development of
T piezoresistive devices was made with the discovery of the piezoresistive effect in Silicon P (Si) and Germanium (Ge) in 1954. The contribution of integratedcircuit (IC) technology I led to the development of the first generation of commercial Si strain sensors, strain gauges R (sometimes referred to as strain gages) in the late 1950s (although both spellings exist, the
word gauge appears to be a more appropriate term to identify a device used in sensing and
C measurement) [1214]. After World War II, the adoption of such devices began to open up S new scenarios in emerging fields such as robotics, with the first examples of tactile sensors, U favoring the birth of new classes of materials that fit the various requirements (e.g. N piezoresistive silicone rubber for the fabrication of conformable devices and the use of A silicon carbide for hightemperature applications) [1517].
The etymology of the composite word “piezoresistive” includes two words of different
M linguistic origin: “piezo”, from the Greek “piezein” (πιε΄ξω, infinitive πιε΄ξειν) which
means «to press, to compress», and is common to other similar effects such as the
D piezoelectric effect, and “resistive”, from the Latin “resistĕre” which means, «to stop». E Although the physical nature of the energy transduction phenomenon is different, the term T was coined in analogy to the piezoelectric effect. By referring to the electric nature of the P devices that we shall describe, and to the etymological meaning of the word E “piezoresistive”, we may argue that such an effect involves a change in the resistance R of
an electric conductor (R=ρ·l/A), where ρ is the material resistivity [Ω·cm], l the conductor
C length, and A the transverse section area, because of a change in its geometrical parameters Coriginated by an external stimulus (at the macroscopic level). However, in certain Amaterials, an equally important part of the piezoresistive effect is due to the change in the
resistivity ρ [12, 18]. While important studies were focusing on semiconductor materials which exploit the energy band theory, investigation was starting on a new class of composites consisting of conducting particles dispersed in an insulating matrix [19, 20].
5
Differently from piezoelectric materials, piezoresistive materials are not inherently able to
generate an electric signal when strained, while piezoelectric materials spontaneously
generate an electric potential difference. The former needs to be supplied by an external
voltage source. If a voltage is applied between the extremities of a conductive bar, the
geometry of which undergoes a deformation as a consequence of the exerted forces, the
current also changes according to the change in the resistance, as Ohm's law states. The
T current that flows through the bar is directly related to the external stimulus (in other words P resistance varies in relation to the mechanical input signal). Piezoresistive sensors are I generally defined as “active sensors”. These, of course, are different from “passive R sensors”, which spontaneously generate an electric signal when stimulated so they do not C need to be supplied by an external voltage source [21]. Contrarily, active sensors need S specific supply circuits depending on the technology of the transducer. Piezoresistive
sensors are also used to perform direct measurements of dynamometric and geometric
U parameters. These may include force (friction, Coriolis, etc.), displacement, deformation, N mass, pressure, flow, level, height, torque, acceleration, cracks, creep, and fatigue [2228]. A Very different materials, such as conductive elastomers, carbon fibers, and pure metals or M alloys — commonly nickel and copper — are involved in the technological processes for
the manufacturing of piezoresistive sensors. More sophisticated processes are based on thinfilm, thickfilm and solidstate technologies [29, 30].
ED 3. Piezoresistive effect in metal conductors T Lets consider an isotropic electrically conductive, cylindrical bar (see Fig. 2a), to which P an electric field Ԑ is applied longitudinally. Assume that R is its resistance in the quiescent E state, at room temperature. Let us now suppose that, upon elongation, because of an applied
tensile force F, the initial value of the piezoresistor, R0, changes to the final value R.
C Through differentiation of the expression
CR
R
R
AdR  d   dl  dA

l
A
and dividing by R we finally obtain
dR
d
dl 
dA 
.
(1)
R  lA
6
Therefore, the initial value of the length (l0) the diameter (d0) and the resistivity (ρ0), after
deformations reach the final values of l1, d1 and ρ1.
We define the “longitudinal strain” εl= dl0/l0 as the variation in length per unit length
and the “diametral strain” εd= dd0/d0 as the variation in diameter per unit diameter.
Because of the increase in length, a reduction in the crosssectional area occurs too, ruled
by Poisson's ratio ν=εd/εl (diametral strain per longitudinal strain). Hence, after the
T application of a tensile strain, the final length and diameter are respectively given by P l1=l0(1+εl), and d1=d0(1εd) while the new crosssectional area is A=π(d0/2)2(1εd)2. I Usually the strain is expressed in microstrain, με, as the ratio of l06 of length unit to the R same length unit. Suppose now that there is also a change in volume during the C deformation; the incremental variation is dV0=A0 dl0+l0 dA0 where V0 and A0 are the volume S and the cross sectional area, in the quiescent state, respectively. On the other hand dV0=V1
V0=A1l1A0l0 from which:
U 2
N dV 0
 
d0
 
(1   l ) 2 l0 (1   l ) 
A0l0
(2)
A  2 
M By developing the square in brackets (1εlν)2, and neglecting higher order infinitesimals
we have
dV 0  A0 l0 l 1  2  .
(3)
D B y considering Eq. (3), with ε l =dl0/l0and following the substitution in Eq. (1) for which l, E A and R, have been used in place of l0, A0 and R0, we finally obtain:
PT dR
d 
 dl 1  2  .
(4)
R l
E Now we can define the longitudinal gauge factor GFl, as the ratio of the change in R C compared to the relative change in length l
CdR / R dR / R
GF l 
(5)
A dl / l
l
and by substituting Eq. (4) into Eq. (5) we can write
GF  1  2  1 d  .
(6)
l

l
7
In most practical cases, however, the strain gauges have a planar geometry with a
thickness t much smaller to the length l and the width W. If an electric field Ԑ is now applied
to a planar strain gauge along the transverse direction w orthogonally to the applied force
F (out of the page in Fig. 2b), the conducting material experiences the socalled “transverse
piezoresistive effect”. The aforementioned analysis applies in this case too, and we speak
of the transverse gauge factor GFt. Table 1 gives the resistivity and longitudinal gauge
T factors of the most common metals used in piezoresistive sensor fabrication. IP 4. The Piezoresistive Effect in Semiconductors
R Piezoresistive effect in semiconductors, which manifests itself at the atomic level is less
evident but much more important than the purely geometrical effect, and contributes to the
C dependence of the resistance variation on the strain. US This effect, discovered by Smith [12], is based on the induced stress modulation of the N electric field generated by the charge transport. It is typical of elastic semiconductor bodies, A such as silicon, germanium and gallium arsenide, and leads to substantial differences in the
M gauge factor previously introduced in Eq. (6). The piezoresistive effect may now be studied
on the basis of the semiconductor theory or of a phenomenological development. Our
discussion is based on the former theory while the phenomenological aspect will be briefly
D outlined, since an exhaustive explanation may be found in [36]. By rewriting the expression E of the electric resistance as a function of the conductivity of the material, σ= qnμ, where n T is the electron concentration, Eq. (l) and Eq. (4) may be rewritten and, after substitution in P Eq. (5) we obtain
E GF
 1  2
1 d 
 1  2  1 d ( n  ) ,
(7)

 n
C which applies for both the longitudinal and transverse strains. In semiconductors, the gauge ACfactor GF is primarily due to the high contribution of the changes that occur in the
conductivity , or equivalently the resistivity ρ, since the geometrical part gives
approximately the same contribution that we have found for metal strain gauges. As stated
in Eq. (7), the changes in conductivity (resistivity) are related to the change in the number
of free electrons and the change in mobility induced by the lattice deformation. Indeed, in
8
crystalline semiconductors the longitudinal and transverse gauge factors may be strongly influenced by the doping level, type, and the crystallographic direction along which the tensional or compressional stress is applied [36].
4.1 Energy band theory
The total energy of a particle (with mass m and velocity v), according to classical mechanics, is given by the sum of the potential energy of the particle U, and its kinetic
T energy p2 /2m (p= mv is the particle momentum). By using abstract quantum mechanical IP operators, the timeindependent Schrödinger equation is given by
R   2 ( x )
 U ( x ) ( x )  E  ( x )
(8)
2m x2
C The separation constant E corresponds to the energy of the particle (for a particular solution S to the above equation, En corresponds to the timeindependent wave function ψn). In U addition, for a particle trapped in an infinite square well (in the onedimensional problem N U(x) = 0 when 0<x<L, U(x) = ∞ when x=0; L), the above equation assumes the form of A the wave equation for a free particle. However, if the potential at the boundaries of the well
has a finite value U0 >E, the boundary conditions do not force the wave function ψ(x) to
M be zero at the barrier, neither within the barrier, nor on the other side. There is a probability
of finding the particle outside of the well, although its energy is less than the potential
D barrier V0 (tunneling effect). The energy of the particle trapped in the potential well is E quantized and its expression is given by
T n 2 2 
h
2
1
P E n 
2m
  2 
L2
(9)
E in which n= ±1, ±2, ±3,..., is called the quantum number. The negative values for the C quantum number are redundant and the unique solutions are related to positive values of n. CEach energy level En of the particle corresponds to a timeindependent wave function ψn. ABy defining the wave number as k=nπ/L, (9) becomes
En
k2 2m
h   2
2
 
.
(10)
The energy of an electron, which moves in a single crystal semiconductor (i.e. a periodic structure with a lattice constant “a”) because of the interaction with the atoms of the lattice,
9
may assume only certain values, while others are not allowed. This situation, compared to
that of a free electron in a vacuum, is depicted in Fig. 3a. The forbidden energy bands occur
around k = nπ/a, while, far from these values, in the allowed bands the electron behaves as
a free particle. The energy plot E(p) of a free electron partially overlaps the energy plot
E(k) of an electron which moves in solids. The key point of piezoresistivity in
semiconductors lies in the modification of the energy gap (the upper and lower values are
T defined for each k = nπ/a) as a result of volume changes under the applied stress. However, P the piezoresistive effect cannot be explained, in a very simplistic manner, on the basis of I the one-dimensional case we have just discussed. R In order to clarify how it occurs in crystal semiconductors (the general treatment is C described by Bloch theory) we need to approach the entire problem by considering the S threedimensional (x,y,z) model known as the manyvalley energy band model. From the
monodimensional problem, after simple mathematical manipulation we obtain two
U different expressions for the electron mass:
N m 
1
,
A d 2 E / dp 2
m* 
2
d 2 E / dk 2
(11)
M in which quantum mechanics defines m* as the electron effective mass. Figure 3b shows
the second derivative of E versus both p and k in (π/a, 2π/a). For a free electron, d2E/dp2 is
D constant and positive. However, for an electron in a periodic lattice d2E/dk2 is not constant
and, in addition, it is negative at the top of the band. Hence, the effective mass m*<m, at
E the bottom of the band, and m*>m, at the top of the band, where the effective mass is also T negative. The result is that when an electric field is applied, the electrons at the bottom and P the top of the band move in opposite directions. For completeness, this fact must be E considered along the three crystallographic directions x,y,z. Along these directions C quantum mechanics associates different wave numbers k1, k2, k3 to the components of the Celectron motion, so m* is strictly related to the direction of the motion of the electron in Athe crystal lattice.
The effective mass is related to the mobility μn of an electron (which we have already
introduced for metal strain gauges) by μn= qt'/m*= v/Ԑ where t' is the mean time between
scattering events in the lattice [37]. For this reason, we must expect that mobility will also
be affected by the direction of the motion of the electron in the lattice. This is shown in
10
Fig. 4 where the constant energy surface near the minima, in the conduction band, are also reported in the threedimensional case, for Ge, GaAs, and Si. The mobility along the principal axis of the constant energy surfaces, which have an ellipsoidal shape for Si, is quite different from that along the secondary axis (see Fig.4c). When we modify the lattice spacing by applying an external stress, we modify the energy levels as well (dashed lines).
When nSi is under tensile stress along the [100] kdirection — longitudinal effect —
T the minimum energy level increases along that direction while it decreases along the other P two. The opposite occurs under compression along [100] — transverse effect. In the latter I case, the stress can break the equivalence of the minima, resulting in shifting upward and R downward in energy. Electrons will then be transferred to the lower lying minima to C minimize the free energy. Thus, mobility decreases and, as a result, the resistivity increases. S Under certain conditions, the electrons in the valence band might also contribute to
conductivity in semiconductors. The phenomenon may be better understood by considering
U the unoccupied states in the valence band referred to as holes. Since holes have a positive N charge, under an electric field, they move (within the valence band) in the opposite A direction from electrons (which move within the conduction band). There is no net current M in the valence band unless at least one electron is removed. However, as for ntype
semiconductors only the electron contribution is important, while for the conduction process in ptype semiconductors only the contribution of hole motion in the valence band
D is relevant. In contrast to nSi, we now have two different energy functions E(k) which E correspond to two different energy bands. Hence, the second derivative of E with respect T to k has two different values in the same k direction which lead to two different effective P masses and mobility values. The difference between the two masses and mobility, E respectively associated to the two different energy bands, increases in the [111] direction C which, for this reason, is the most sensitive to stress application.
If we now apply a traction to the pSi along the [111] direction, the two bands split apart
ACfrom each other and the respective hole populations change, since holes— which lose
energy— move to the top where they have decreased mobility, resulting in “heavy holes”; the “light hole” band lowers with respect to the former one (see Fig. 5).
As the hole population with decreased mobility increases (the average hole mobility μp decreases), the conductivity σp = qpμp decreases and consequently the resistivity increases
11
[38]. In contrast to n-type silicon, which has a negative gauge factor of about 135, Smith
found a positive gauge factor of up to 175 in ptype Si massive bodies [12]. Another
important consideration concerns the doping level in both cases; indeed, as regards low
impurity concentrations, the percentage of carriers which moves to lower energy levels is
larger as compared to that of highlydoped silicon. The consequence is that lowdoped
materials have a high gauge factor.
T 4.2 The phenomenological approach IP On the basis of the phenomenological development in threedimensional space, the
relative resistance change may be expressed as a function of the longitudinal and transverse
R piezoresistive coefficients [36]. The electric field vector, Ԑ, is related to the current vector, C  by Ohm's law Ԑ =ρ  , through the resistivity tensor ρ (a 3x3 matrix). In crystal having S a cubic structure, such as Ge, GaAs, and Si the number of the resistivity matrix elements is U reduced to three (ρ1, ρ2, ρ3 = ρ) by symmetry, which in piezoresistive materials depends on
three normal and three shearstress components. From the phenomenological point of
AN view, the piezoresistive effect may be described by relative resistivity changes dρ/ρ now
M related to the stress components by a 6x6 matrix of πij elements called piezoresistive
coefficients [Pa1]. When the symmetry is cubic, the number of independent piezoresistive
coefficients is reduced to three: π11, π12 and π44. The longitudinal and transverse
D piezoresistive coefficients may now be expressed as
E   l
  11
 ( 11
  12
44
)
2 1
2 1
2 1
2 1
2 1
2 1
T   t
  12
 ( 11
  12
44
)
2 1
2 2
2 1
2 2
2 1
2 2
(12)
P in which α1, β1, γ1 are the direction cosines along the longitudinal axis of the body with E respect to cubic axis (the same as cubic axis and current flow), while α2, β2, γ2 are the C direction cosines along the transverse axis of the resistor [39]. Longitudinal and transverse
piezoresistive coefficients are very important parameters in long resistor semiconductor
ACdesign since they relate the relative change in resistivity to the applied stress
d
   
ll
tt
(13)
in which σl and σt now represent stress, not conductivity. The direction of diffused or ion implanted resistors with respect to crystallographic direction, when properly chosen in a
12
bridge configuration, allows us to sense only stresses applied in preferential directions.
Usually, psilicon is preferred for the making of semiconductor strain gauges since both
longitudinal and transverse piezoresistive coefficients have a maximum in the <110>
direction while nsilicon has a minimum in that direction [39].
Micromachined semiconductor piezoresistive devices and integrated circuit technologies
allow the making of microsensors and microactuators for working at temperatures under
T 120 °C. The extreme ease with which it is now possible to etch very thin semiconductor P cantilevers, allows the making of monolithic devices for both pressure and acceleration I measurements. R A different class of new semiconductors—specifically, Silicon carbide (SiC)—has been C extensively investigated for the fabrication of hightemperature devices [4042]. In S general, SiC have superior properties as compared to silicon in terms of elastic modulus,
thermal conductivity, sublimation temperature, and chemical inertness. SiC forms stable
U polytypes (more than 200) which also influences the position of the conduction band N minimum in the kspace. Thus, although briefly reported for completeness, the theory is A limited only to Si while a more exhaustive treatment is available in the literature [43]. In M Table 2 the longitudinal gauge factors of the most common semiconductors for
piezoresistive sensor fabrication are reported. An important consideration concerns the influence of temperature because of changes in environmental conditions or piezoresistor
D selfheating. If the temperature changes from Ta to Tb, the resistance changes from Ra to E Rb, given by
T R b  R a 1   Tb  Ta  .
(14)
P Temperature compensation includes passive and active techniques. In the first case, extra
E components (e.g. fixed and temperaturedependent resistors) are used to compensate the
C errors of offset and sensitivity [44, 45]. Often the use of dedicated electronic circuits is
Cnecessary and these will be discussed in the section dedicated to readoutcircuit design.
AActive techniques usually include digital compensation of the temperature and the use of
additional temperaturemonitoring units to reduce the abovementioned errors in order to
decrease, if possible, the incidence of temperature variations (e.g. digital calibration,
thermostatic control) [4648]. The gauge factor also changes with temperature, and there
are substantial differences between the thermal expansion coefficients of the support (the
13
massive body being tested), the gauge, and the bonding material. There are gauges which self compensate only for particular material supports; otherwise the effects of temperature must be electrically compensated [49, 50].
5. Piezoresistive Effect in Polymer Composites
T Polymers are widely known as insulating matrices with excellent optical and mechanical IP properties. In the last 20 years many attempts to fabricate polymeric sensors by modifying
their structure have been carried out. In the literature a great number of researchers have
R investigated the electric properties of polymers with incorporated particles (i.e. fillers) and C the conduction mechanisms. The tool employed for the description of electric conduction S in polymer composites (i.e. polymers and dispersed conductive particles) is called the U percolation theory. At low filler concentrations (see Fig. 6a), metal particles are quite N isolated and dispersed inside the insulating matrix resulting in a high electric resistance. A By increasing the concentration of the filler, a conductive path is established and thus a
M drastic reduction in electric resistance comes about, defining the socalled “percolation
threshold” (see Fig. 6b).
This is a simplified explanation but in reality different parameters are involved in the
D conduction mechanisms (e.g. particle geometries and properties, insulating matrix E properties, and polymerparticle interaction). The conductivity of an insulating mixture
above the percolation threshold can be expressed by using the model proposed by
T Kirkpatrick and Zallen as
EP 
  0X
B
XC
(15)
C where X is the volume fraction of the filler, XC is the volume fraction of the filler when the
percolation threshold is reached, and B the power of the conductivity increase after
ACreaching the threshold. The latter is dependent on the properties of the filler (e.g. geometry)
[54].
Several comprehensive and exhaustive reviews of different percolation models have
been published, which even report on a wide range of supporting studies together with the
experimental evaluations of the different polymers and fillers tested [54, 55]. When the
14
distance between the conductive particles is 10 nm or less but there is no physical contact, the tunneling conduction mechanism occurs, characterized by a power law currentvoltage relationship [56, 57]. Conventional fillers used for increasing the electric conductivity of polymer composites are categorized as microfillers, the dimensions of which are in the microscale (e.g. carbon micro fibers, graphite), or nanofillers e.g. carbon nanotubes (CNT), nanosheets of graphite/graphene, carbon black, etc. will be better discussed later.
T 6. Geometrical EffectBased Strain Gauges IP 6.1 NonMetal Strain Gauges R Conductive rubber and carbonfiber strain gauges have been widely investigated in the C field of robotics, particularly for the fabrication of tactile sensors. The goals were to achieve S compliance, lightness, sturdiness, and low cost products; however both conductive rubber U and carbonfiber strain gauges suffer nonlinearity and a high degree of hysteresis.
Conductive rubbers are usually fabricated by incorporating conductive particles of
AN different types and dimensions, into a siliconebased matrix. Their sturdiness and M compliance rendered them one of the most suitable materials for important applications in
the field of robotics for the fabrication of tactile sensors able to withstand and adapt to damage and inaccuracy during robot positioning and the grasp. Row-bycolumn matrices are one of the most widespread configurations, an example of which can be seen in Fig. 7,
D fabricated with a Mylar film on silicone rubber. E In the literature, polyurethane foam has been investigated with an eye to increasing the T compliance. The foam was coupled with conductive wires for the electric connections P (made of conductive rubber) and a hybrid technology was realized [58]. The exertion of a E force over the matrix causes variations in the contact area of the rubber sheets resulting in C a variation of the electric resistance. At low loads the sensor response follows the law R = Ck/F where constant k has the dimension of Ω·kg and F is the applied force. ADifferent polymeric insulating materials have been adopted for nonmetal strain gauges,
such as polydimethylsiloxane (PDMS), polypropylene (PP), polycarbonate (PC), polymethyl methacrylate (PMMA), polyelectrolytes (PE), flexible epoxy and polyvinyl alcohol (PVA), to cite just a few examples [5964]. Generally speaking, carbon is the most common filler used in polymerbased composites. The allotropic structures of carbon, such
15
as carbon nanotubes and graphene, have recently been investigated for piezoresistive sensing applications. Graphene is a singlelayered (one atom thick) twodimensional array of carbon hexagons. First discovered in 1960 and later isolated in measurable quantities in 2004 by Geim and Novoselov, graphene has attracted quite lot of interest because it presents excellent mechanical, thermal and electric properties as compared to other conductive fillers [6569]. Coskun et al. have proposed graphenebased elastomers as
T flexible polymer sensors with promising characteristics for detecting dynamic forces [70]. P The inherent mechanical property of this new class of sensors to detect both small and large I vibrations lies in its internal honeycomblike structure, and it depends on the quantity of R graphene used during the fabrication procedure [71]. Rinaldi et al. studied a novel C lightweight piezoresistive sensor based on PDMS polymers in a foam format coated with S multilayer graphene nanoplatelets for applications requiring high sensitivity, such as
wearable health care systems and humanmachine interfacing devices [72]. Ye et al.
U investigated flexible and wearable strain sensors based on graphene oxide and N polyethylenimine composites; these exhibited exceptional properties in terms of A sensitivity, linearity, stretchabilty and durability [73]. M Carbon nanotubes, first discovered by Iijima in 1991 and synthesized in 1993, have
attracted a remarkable degree of interest as a possible filler material for the lightweight structures of polymers for numerous applications [7477]. Unlike conventional strain
D sensors, (i.e. metallic and semiconductor) CNTs can be embedded into structural materials E and can operate on a nanoscale as both multidirectional and multifunctional high T resolution sensors. Based on their structures, CNTs can be classified as single or multi P walled, referring to the numbers of layers a CNT consists of Polymers in conjunction with E CNTs have been used in many applied fields. A carbon nanotubepolydimethylsiloxane C (CNTPDMS) device has been developed for electronic skin applications in order to mimic
the complex anatomical structure of the fingertip [77]. Yamada et al. presented a novel
ACstretchable sensor for applications such as human motion detection, health monitoring, and
rehabilitation. The device consists of aligned singlewalled carbon nanotubes placed on PDMS substrates, and is able to detect strains 50 times greater than conventional metal strain gauges [78]. Cho et al. proposed threedimensional nanoporous electrodes based on polymer substrates loaded with CNTs, achieving a gauge factor of up to 134 at a maximum
16
tensile strain of 40 %, and the potential applications of these could be the dynamic detection of human joint motion [7781].
Basically, the piezoresistive properties of the conductive polymer composites are related to the type and the concentration of the filler that is added to the polymer matrix. Table 3 reports the resistivity values of a few conductive composites depending on the percentage content of the fillers used. As regards the gauge factor of conductive polymers loaded with
T carbon fillers, Shang et al. showed a nonlinear behavior of the gauge factor as a function P of the mechanical deformation for carbon black/silicone composites [82]. That result was I different from that of other carbonbased polymers. For instance, Wang et al. reported a R constant gaugefactor value for graphene/PDMS composites testing different filler C concentrations [83]. A similar result was found for strain sensors made of CNT/PDMS S composites [84].
Conductive polymer composites are commonly synthesized by mixing carbon fillers and
U polymer materials using lowfrequency ultrasound with or without the addition of N detergents [85]. This preparation method is quick and simple, overcoming limitations of A metal and semiconductor systems. However, one of the main challenges is that it is usually M difficult to homogenously distribute the carbon fillers within the polymer matrix [86].
Another drawback in the fabrication of conductive composites is the choice of the mix ratio of the carbon fillers and the polymer material. In fact, the mixing ratio determines the
D conductivity and the mechanical deformability of the conductive composites. High E conductivity involves a reduction of stretchability, and this aspect has restricted the T application fields of conductive composites especially as far as stretchable electronics is P concerned [87].
E6.2 Metal Strain Gauges C Undoubtedly, metal strain gauges are one of the most affordable and reliable Ctechnologies. The transducers are usually made using a metal strip several micrometers Athick, patterned in a meandering geometry (see Fig. 8) to increase the length of the resistor
over a small area (standard linear dimensions range from l mm up to a few cm). However, the width can be greatly inferior to the length l (see Fig. 8b). Thicknesses of about 5 μm are quite common resulting in a resting resistance which can range from 120 Ω to 750 Ω, even though transducers with larger values are also commercially available. In these cases,
17
the metal foil grid is set in a plastic or other type of support (paper, polyimide or other insulating polymers), resulting in an overall thickness of about 25 μm.
The temperature of operation of such devices can reach about 130 °C. The strain limit is about 40·103 με, while longitudinal and transverse gauge factors are about two and zero, respectively. However, the gauge factor also depends on the resistivity of the material ρ = (qnµ)1. In metals, not one of these parameters is influenced by the experienced stress, (the
T reason for this has been previously discussed in section IV treating the piezoresistive effect P of semiconductors). I Metal foil technology is wellsuited to be mounted closely to the body which is subject R to strain (these are often referred to as “bonded” strain gauges). Conversely, the socalled C “unbonded” strain gauges are fabricated using different conducting wires and find different S applications as force transducers. Bonded gauges are directly placed on the surface of the
massive body, the strain of which must be measured. Because of its particular geometry,
U the piezoresistor is mounted with the grid parallel to the direction of the dominant strain N “longitudinal strain” although the massive body may also experience a secondary A “transverse strain”, in the orthogonal direction; this, however, is totally neglected because M of the null GFt. Actually, the particular meandering geometry of bonded gauges makes
them sensitive to transverse strain as well. However, the contribution of the very small parts of the conductor in a widthwise sense is negligible as compared to the contribution
D of the lengthwise conductor. In Fig. 8c a geometrical arrangement of three strain gauges E called a “rosette” is shown, for use in multicomponent force fields. T Nanomaterials such as metallic nanowires have also been used for the design of P piezoresistive sensors, especially for electronic skin applications. Different materials have E been employed for the fabrication of nanowires [9397]. Silver and gold nanowires have a C high conductivity (63·104 S/cm and 45.2·104 S/cm, respectively), ensuring low power
consumption during the sensing operation [98]. However, they are expensive to fabricate.
ACCopper nanowires present a conductivity (59.6·104 S/cm) similar to that of nanowires made
of silver or gold, but they are much cheaper to make. The main drawbacks related to the use of copper nanowires are the thermal oxidation and chemical corrosion that occur in harsh conditions, which leads to the loss of conductivity over time [99].
18
6.3 ThickFilm Strain Gauges Strain gauges fabricated in thick film employ an organic fluid suspension made with conductive glass particles (i.e. resistive inks), deposited on a ceramic substrate (an alumina film 250500 μm in thickness) [100]. In thickfilm technology, the typical thickness that can be achieved is on the order of several microns up to several hundred microns, and this is strictly determined by the
T fabrication process [101]. Thickfilm piezoresistive sensors are advantageous and are used P in many applied fields, above all for their compatibility with difficult environments and I their low fabrication costs [102109]. Factors influencing strain sensitivity are the R variations of resistivity, conductivegrain characteristics, the strain (e.g. elongation or C compression) and the electric field. Although we have included thickfilm strain gauges S among those based on the geometrical piezoresistive effect, the conduction mechanism and
the strain sensitivity are primarily dominated by the tunneling effect, which has been
U previously discussed in the semiconductor straingauge section. Typical thickfilm N longitudinal and transverse gauge factors are on the order of a few dozen, and find ample A application in situations where there are high temperatures and harsh environments. At the M moment thickfilm technology, although inadequate for largescale integration, is finding
application in hybrid technology (e.g. assembled close to integrated circuits).
D 6.4 ThinFilm Strain Gauges
SnO and SiO cermet thinfilms deposited onto ceramic substrates have been employed for
E strain gauge fabrication in the electronics industry [109]. Other types such as Ni and Ta T may be deposited by means of vacuum processes, evaporation, sputtering or plasma P chemical vapor deposition. The miniaturization of these devices is both possible and E economical, in particular when great accuracy is required [110]. The most common C technological process of fabrication — particularly employed when accurate measurements Care required — consists of sputtering the gauge material directly on top of the massive body Abeing tested, and subsequently etching it according to proper geometries. The maximum
operational temperature reaches about 150 °C [3]. Thinfilm strain sensors have attracted a great deal of attention in a variety of applied
fields, including electronic skin and healthmonitoring systems. Metallic thinfilm sensors using gold as the piezoresistive material are commonly used for measuring the tactile
19
sensitivity and forces exerted during the locomotion of small biological organisms [111]. In Xian et al. metallicglass thin films are used as flexible strain sensors for electronic skin applications [112]. This material consists of different metals (zirconium, copper, nickel and aluminum) deposited on a flexible polycarbonate substrate. Engel et al. have developed an artificial skin that consists of a contact force and hardnesstesting sensor based on a piezoresistive transduction mechanism. They fabricate their strain gauges using thin films
T made of nickel and chromium [113]. As compared to other thinfilm strain gauges (CNTs, P graphene, metals or alloys and conductive polymers), metallicglass sensors combine I advantages in terms of conductivity, flexibility, manufacturing costs, and sensitivity. In R addition, metallicglass strain sensors have shown very low temperature coefficient C besides antimicrobial properties. All these properties make metallic glass a promising S material, especially for electronic skin applications.
In the case of metallic thinfilm sensors, the gauge factor is mainly based on geometric
U effects, and is about 2 [113]. The gauge factor is therefore comparable to that of metal N strain gauges, but metallic thinfilms have little stretchability, as do most metallic A materials. In order to increase the stretchability of metallic thinfilms, they are put onto M polymeric substrates in curved or wavy shapes [114116].
7. Piezoresistive StrainGauge Applications
D 7.1 Force sensors E Forces change the quiescent or motile state of a body to which they are applied. T According to Newton's second law, under the application of a force F = mdv/dt, a body of P mass m moves with an acceleration dv/dt. In the last 20 years, especially in the field of E robotics, intensive efforts have been devoted to the development and sensorization of
humanoids [117]. Contact sensors are of fundamental importance for the measurement of
C the physical forces that occur when a robotic endeffector makes contact with an object. In ACmost of the recent literature having to do with robot sensorization, an approach based on
the bioinspired mechanoreceptor viewpoint (e.g. Merkel, Ruffini, Meissner and Pacini corpuscles) for tactile sensing is used [118, 119]. Each receptor is thus dedicated to a particular stimulus, such as static or nonstatic, which corresponds to the detection of static stress and vibrations [120]. Both as transducers and arrays, tactile sensors are required to
20
perceive an incipient stimulus, and to identify and detect the orientation/position of the target, giving exteroceptive information during its task [121]. A valid set of performance criteria that tactile sensors should have was suggested back in the 1980s and then progressively refined, as reported in Table 4.
More recently, the advent of the first and second waves of robotic systems for human
mimesis and rehabilitation consequently changed the requirements in terms of
T piezoresistive sensor integration. Force measurements are usually performed by combining P shear stresses with cantilever beams of different configurations [126]. I Most commercial and noncommercial strain gauge sensors for force measurements are R based on small deflections of beams, cantilevers or diaphragms [127130]. Usually at least C two or more gauges are bonded onto the opposite faces (top and bottom) of a cantilever or S a membrane fixed at one or both ends, respectively. The need for flexible, compliant and U conformable devices is accelerating their development in the field of composite materials
as previously discussed, which combine mechanical flexibility and resistance and can
AN protect the sensors from the external environment. Based on conduction mechanisms, the M material/composites employed in tactile sensors can be further divided into strain gauges
(e.g. metal or siliconbased gauges), percolative (e.g. conductive rubbers, carbonblack
and carbonnanotubebased composites), and quantum tunneling (thick film, metal
D dispersed particlebased sensors) [124, 131133]. Recently, most of the commercial
sensors dedicated to human touch mimesis are implemented with Force Sensing Resistors
E (FSR), consisting of conducting interdigitated electrodes deposited on a flexible polymeric T film bonded on another conductive polymeric film. A spacer between the two films allows P an electric contact to occur when a force is applied. These FSR are unusually employed in E highaccuracy applications [7]. C Concerning their functioning principle, in most of the integrated piezoresistive sensors, Cthe force, applied at the end or in the central region, deflects the beam and induces a Acompression or an expansion of the gauges depending on the beam geometry and
constraints. According to Hooke's law the modulus of elasticity η=s/ε, stress/strain, is
given, for a traction FT or compression FC respectively, by
, F / A
T  T L / L
.  C  F C / A L / L
(16)
21
The electric output signals of the gauges are proportional to the applied force through
longitudinal displacement (see Fig. 9).
The major drawbacks of the classic (semiconductor and metallic) strain gauges are their
mechanical fragility, and scarce thermal stability. In order to overcome these
disadvantages, the use of flexible substrates was investigated both by integrating rigid
transducers and/or by including microparticles in order to decrease the stiffness of the
T sensors. P A typical process for rigid transducer integration is the socalled SilicononInsulator I (SOI), in which an intermediate oxide layer is used to stop the etching of the bulk Si R substrate (see Fig. 10a). The Si wafer is also oxidized on the bottom and a large window is C subsequently opened. This opening serves to etch the bulk Si in the last steps. On the S opposite side the silicon is etched away as far as the intermediate oxide stop layer, to form
the cantilever. A new thinoxide layer is grown as a passivation layer. Contact holes are
U opened in sequence, after which a thin metal (e.g. aluminum) layer is sputtered, patterned N and etched in order to contact previously diffused resistors (see Fig. 10b). After protection A of the top layer with insulating polymers, the bulk silicon is etched through the large M window. Finally, the original oxide layer is etched and removed to form the cantilever (see
Fig. 10 c, d).
D 7.2 Displacement sensors
Strain gauges mounted in order to sense both the tension and the compression of the
E beam are frequently used to make displacement sensors. A force sensor can be fabricated T by a calibrated displacement sensor with a wellknown stiffness. In Fig. 9b, the beam is P deflected by a sensing shaft and the displacement can be measured using the following E formula:
CFd 2 3D  d 
 6 I
(17)
ACwhere D is the length of the beam, d is the distance at which the force F is applied, and I is
the moment of inertia of the beam. Considering a given displacement at the center, the
stress/strain is proportional to its thickness thus imposing constraints on the placement of
the transducer element and the thickness of the beam [134]. Cantilevers and beams are
22
commonly designed and fabricated as displacement sensors using various topologies (see Table 5).
Working at low frequencies is important for reducing 1/f noise and even Johnson noise inherently due to thermal energy in the resistor. Long time stability (in terms of hours) is also desirable [138].
T 7.3 Weight sensors P One other application in which force transducers are used is that of weight measurements I [139]. Weight can be seen as a particular force; more precisely it is the force which acts on R any object immersed in a gravitational field. Hence, the weight measurement may be turned C into a force measurement by taking into account the fact that the terrestrial gravitational S field changes according to geographical characteristics. The gravitational acceleration
decreases by about 0.53 % by moving from the poles to the equator and by about 0.03 %
U by moving from sea level to 1000 m [140]. AN 7.4 Pressure sensors
M Strain gauges for pressure measurements convert pressure variations (force per unit area)
into resistance variations. Both bonded and unbonded metal strain gauges as well as sputtered thin film gauges have been used for this application. For measurements of the
D order of a few hundred kgm2 semiconductor strain gauges are also used. The transducers E are usually located on the backside of a membrane, opposite to where the pressure is
applied.
T The micromachining of silicon is currently a mature technology for the fabrication of P pressure sensors although Si is easily broken (maximum strain of 2 %) [141]. This is a E consolidated technology which makes the fabrication of devices possible that can sense a C very wide range of pressures; this can be done by designing the transducer with the proper Cdimensions (e.g. diaphragm, beam, cantilever) [142]. The basic design structure among Amost types of pressure sensors is quite similar: a diaphragm, which flexes upon pressure,
which is the parameter to be evaluated. Mechanical deflections/strains are thus transduced through properly located piezoresistive elements [143145].
Notwithstanding the high gauge factor of the siliconbased pressure sensors, attention should be paid to the temperature coefficient of piezoresistivity (0.27 %·°C1) and doping
23
concentration, both of which impose limits on the temperature range and compensation circuits [146].
Although different canonical forms of integrated piezoresistors are often employed, Fig. 11 shows a typical arrangement of a cruciform pressure sensor.
7.5 Flow sensors A particular application for pressure sensors concerns the indirect flow measurement of
T gasses or liquids. These sensors are classified as nonthermal devices, and the pressure IP variation due to variations in the flow of the substance is measured through a mechanical
linkage between a diaphragm and the strain gauges.
R The diaphragm, which is in direct contact with the fluid, converts a pressure variation C into mechanical motion which is then accurately transmitted to a strain gauge bridge. When S fluids are not highly corrosive, the strain gauge bridge is located directly on a membrane U or a cantilever (see Fig. 12). Thin layers of insulating material are nevertheless used to
prevent possible corrosion due to long periods of exposition to the fluid, short circuits due
AN to fluid conductivity, or damage due to sensitivity to high temperatures. M Piezoresistive flow sensors have been applied in biomimetics, where the technology is
used to mimic nature. Examples of flow biosensors can be found in vertebrates such as fish. These sensing elements consist of tiny structures known as hair cells, which are
D located in a wellorganized manner on their bodies and act as flow sensors that monitor E the surrounding environment for tasks related to motion, orientation and prey localization
[147]. Invertebrates such as spiders also use hair cells as airflow sensors to detect very
T slight displacements [148]. Recent studies have highlighted the role of hair cells in bat P wings in connection with flight maneuverability [149]. Biological hair cells are also found E in humans and other vertebrates for sensing acoustic vibrations and equilibrium [150]. C Artificial biomimetic flow sensors based on the piezoresistive principle have been Cfabricated using different geometries and materials [151154]. Shen et al. have exploited Athese sensing elements to fabricate piezoresistive flow sensors based on MEMS technology
to measure the flow rate in the tubes used for intravenous infusion administration. The sensor is composed of a vertical hair located on a polymer diaphragm plus a gold thinfilm that realizes the transduction [155].
24
A general drawback of the piezoresistive flow sensors is the mechanical damage induced by high flow velocities. Flow sensitivity and time response are the common parameters used to characterize this type of sensor, which are strictly related to the size of the cantilever used for the detection of the strain. Wang et al. reported that the flowrate sensitivity of air flow sensors increases when wider cantilever beams are used. But the response time was found to increase as the cantilever width was decreased [156]. Data for piezoresistive flow
T sensors are reported in Table 6. IP 7.6 Torque sensors
Torque is the moment of a force applied to a body rotating around an axis in order to
R accelerate or decelerate its rotational motion. Hence, a torque transducer senses the shear C stresses in a torsion bar, the axis of which rotates as a result of the applied torque. If Ft is S the tangential force applied to a point far from the axis of a distance d, the torque is given U by τ= Ftd. = I·dω/dt, where ω is the angular velocity. Usually bonded metal foil and
semiconductor strain gauges in a cruciform arrangement (see Fig. 13), are used for this
AN application. The strain gauges are placed at 45° angles relative to the main axis in order to M maximize the sensitivity. One pair of sensors is designated for detecting tensional strains.
The other pair can measure compressive strains. Torque sensors are useful in many industrial applications, including robotics. For
D instance, these types of sensors have been used successfully in the rehabilitation field to E support patients regaining mobility of the wrist joint [158]. Polymerbased composite
materials have also been used to make piezoresistive torque sensors for implants and
T artificial joints, with the aim of increasing biocompatibility and compatibility with P electronic circuitry while decreasing the manufacturing costs [159]. The use of E piezoresistive torque sensors in robotic applications is still a question of compromise C between sensitivity and torsional stiffness. In fact, these two factors are inversely Cproportional to each other. Moreover, other issues can be related to the placement of the Astrain gauges on the body of the sensors, and to miniaturization, although some
advancements have been reported recently in terms of design optimization that aims at overcoming these drawbacks [160].
25
7.7 Acceleration sensors Strain gauge sensors for acceleration measurements have the typical configuration of a force sensor terminating in a seismic mass. Accelerometers convert the alternating displacement of a massspring system (with dumping), around a quiescent position, into a variation of resistance. As in previously discussed sensors, acceleration measurements are performed by mounting two gauges on the opposite faces of a cantilever beam at the end
T of which a body of mass m is located (see Fig. 14). The damping medium is usually a P viscoelastic fluid such as silicon oil (not shown in Fig. 14). The top and bottom strain I gauges work alternately in tension or compression depending on the acceleration or R deceleration (negative variation of body velocity) of the seismic mass. The mass is sensitive C to orthogonal acceleration on the main surfaces of the cantilever, the displacement of which S is proportional to the acceleration. Since m is known, the mass acceleration can be found
by using Newton's second law F=mdv/dt. Devices are usually based on metallic bonded
U strain gauges as well as semiconductor strain gauges. The first silicon micromachined N accelerometer was developed at Stanford University in 1979 [161]. The piezoresistor A device is included within an electronic circuit that provides an electric signal linearly M proportional to the acceleration. The whole system is only a few millimeters in size.
In accelerometer production, the etching process may be controlled in order to obtain the seismic mass at the end of the cantilever. When accelerated, the cantilever bends and the
D resistance values of the diffused piezoresistors change. The strainsensing resistors are E placed at points of maximum stress and the seismic mass may be suspended along one edge T or from points along both edges. P Typical characteristics of piezoresistive accelerometers are frequency response, E sensitivity (expressed in terms of mV/g), and linearity. More specifically, they have a broad
frequency range (from dc up to a few kHz), a sensitivity of up to 25 mV/g depending on
C the gauge mounted on the cantilever beam, and a dynamic range of ±1,000g with an error ACof less than 1 % [162]. Other advantages are the low fabrication costs, the fact that its
lightweight and the possibility of miniaturization. Notwithstanding the great sensitivity and good frequency response, piezoresistive accelerometers have some limitations such as the negative influence of high working temperatures on output performance, and the bandwidth that has to be traded off with sensitivity.
26
Acceleration sensors based on piezoresistive technology are widely used in the automotive, medical and robotics fields, as well as others [163]. An interesting use of piezoresistive accelerometers is related to the proprioception of robots, which provides information about their positioning and orientation [164]. Piezoresistive accelerometers are also used for measuring human tremors, a clinical manifestation characterized by involuntary movements of body parts [165]. The frequencies of neurodegenerative diseases
T — which are the cause of tremors — range from a few tenths of Hz up to 25 Hz, depending P on the medical condition of the patient [166]. The good frequency response they give at I very low frequencies together with their excellent sensitivity represent the main R characteristics that legitimize the use of piezoresistive accelerometers in tremor diagnostic C systems.
S 8. Electronic Circuits for Piezoresistive Devices U The electric output signal of a piezoresistive strain gauge in its original form is useless N for practical purposes. Before further analog or digital conditioning, it needs to be A amplified by lownoise circuits. The first stage of the electronic acquisition unit, the
preamplifier, is the most important block since, in general, it matches two blocks of a
M different nature, the transducer itself and the global electronic circuit, made with other
cascaded stages which are usually general purpose analog or digital circuits, and, less
D frequently, specialized circuits [167169]. A classic conditioning circuit consists of a E Wheatstone bridge through the generation of a nonzero voltage V in response to bridge T imbalance generated by one or more of the resistive elements (see Table 7). EP Basically, the piezoresistive sensor consists of a Wheatstone bridge or a halfbridge
circuit, the arms of which are made with dummy, RD, and strain gauges, RG = RD + ΔR,
C (the former are used for compensation purposes and are mounted onto the unstrained Cportion of the body being tested) [170]. Figure 15 shows a full Wheatstone bridge. There Aare four arms in which from 1 up to 4 strain gauges are connected to three, or fewer, dummy
gauges.
27
Two nodes of the bridge are connected to the supply voltage V, while the other two are connected to the electronic preamplifier, mounted in the differential dc configuration, the output of which is related to the strain gauge resistance variation by
Vo
RF RD
 1
V
,
R D / R F 2    / 1   
(18)
where ϑ is R/RD. Apart from the full bridge configuration (i.e. load cell), resistive bridges
T suffer from an inherent nonlinearity as long as ΔR/RD <<1, in addition to the non IP linearities arising from other sources. R The outputoffset voltage, which may be of the same order of magnitude as the
transduced signal and must therefore be compensated, is given by VOS=Vio
C (RD+RF)/RD+(I2I1)RF, where Vio is the input offset voltage of the operational amplifier, S and I1, and I2 are the noninverting and inverting input bias currents, respectively. For this U preamplifier configuration, which has very low input impedance, an operational amplifier N with a good commonmode rejection ratio, CMRR, is suggested. Figure 16 shows a better A topology of the differential dc amplifier, where the output of the bridge (which, here too,
may be made using from 1 up to 4 strain gauges) is connected to the socalled
M instrumentation amplifier [3, 167].
This topology, also known as a differential buffer amplifier, offers many advantages as
D compared to the former one. First of all it has very high input impedance. In addition, its E gain may be easily changed by modifying the value of the resistor R1. Then, if the second T stage is carefully balanced, the preamplifier has a very high capability of rejecting P commonmode (CM) signals. Indeed, since VCM=V01=V02, the commonmode noise E pickup is completely rejected by the second differential stage, which has a commonmode C gain ACM=0. The differential gain of the preamplifier is given by Ad=1+2RF/R1.
A third topology is sometimes used in combination with the half bridge. This is the
ACsimplest and least used circuit. However, for particular applications it has some advantages.
The sensor consists of two arms which are respectively made using only one strain gauge
and one dummy gauge in a potentiometric configuration (see Fig. 17) [171].
The bridge arms are connected to a currenttovoltage converter made with a lownoise
operational amplifier. This configuration is suggested when the half bridge is connected
28
very closely to the converter. Indeed, in contrast to both the differential dc and buffer amplifiers, the CM signal is not rejected by the converter. Figure 18 shows another arrangement in which two similar configurations, if required, may be mounted on the opposite faces of a cantilever force sensor [3].
The strain gauge couple senses the pressure signals that have the same amplitude but are opposite in polarity. The pushpull voltages, due to a mechanical stimulus, may be added
T in modulus and amplified, if necessary, by a second differential stage. This circuit topology P allows the doubling of the electric signal generated by the pressure on the cantilever and a I drastic reduction in the noise generated by the transducers. As for the instrumentation R preamplifier, the CM signal is now rejected by the second stage. The output of the upper C or lower channel of the first stage does not depend on the strains induced simultaneously S on both piezoresistor strain gauges, as would happen if a differential buffer amplifier was
used. In the quiescent state, both the channels may be tested and calibrated separately. The
U gain is selected by using fixed resistors instead of variable resistors, which is preferable N when the sensor is included in mobile small effectors. Finally, the sensitivity may be A increased by increasing the bridge supply voltage. In contrast to the differential buffer M amplifier, in this particular topology each operational amplifier of the first stage does not
suffer from commonmode voltage limitation. The only limit in supplying voltage is imposed by the piezoresistive strain gauges because of selfheating, as well as the normal
D limitations of the gauge elements (45 V for most commercially available strain gauges). E If εU and εL are, respectively, the strain on the upper and lower strain gauges, when an T external force is applied to the cantilever (see Fig. 9a), the variations in the resistance of P the upper and lower sensing elements are respectively GF= ΔR/RU(1/εU) and GF= E ΔR/RL(1/εL). Let V be the bridge supply voltage, RF the feedback resistance of the C currenttovoltage converter, and RD equal to RU, RL, the resistance of the strain
gauge in the quiescent state. Each converter output V0= V(RF/RD)(±ΔR/RD) is
ACproportional to the ratio ±GFε, where ε is the upper or lower strain. Moreover, the signal
at the output of the differential dc amplifier is proportional to GFεU  GF(εl). The output offset voltage of each converter is given by the following expression VOS= RF·(I2+2Vio/RD). In each of the analyzed configurations, temperature compensation may
29
be performed by inserting a resistor in series with the supply voltage or with a properly chosen arm of the bridge [52], [53].
Power consumption has become an important limiting factor in the development of piezoresistive sensors, especially if the power supply limits the design (e.g. wearable devices for biomedical and home applications) [172, 173]. In voltage mode readout circuits, a higher nominal value strain gauge yields lower power consumption while, for
T current mode circuit topology, the opposite happens [45, 172]. The effect of selfheating P is the cause of frequent measuring errors unless the power is kept as low as possible [174]. I Optimal length is often a compromise between the reduction of selfheating (shorter strain R gauge) and the increase of the transverse loading factor (longer strain gauge) [53]. The C typical power consumption of a resistive gauge element is in the mW range while for other S technologies, such as that of piezoelectric or capacitive sensors, it can be reduced to a few
hundred nW or less [175177]. Compared to passive piezoresistors that need a voltage
U source to measure the strain, piezoelectric sensors generate an electric potential difference N in response to a mechanical stimulus. Therefore, heating issues are limited since they do A not require a power source to operate. Differently from metals and semiconductorbased M piezoresistors, thin conducting polymers must be driven at submW to avoid excessive
selfheating due to the large temperature coefficient [178]. Being closely related to the material and size of the element, the everincreasing need to scale down the device into
D the nanoscale range has emphasized the heating issue which is detrimental to noise and E sensitivity [53, 179]. T As previously highlighted in this section, while in the simplest cases piezoresistive P sensors do not require complex conditioning circuitry, different strategies have been E implemented for working under lowvoltage/lowpower conditions, at the same time C increasing the accuracy that is also limited by errors of the electronic interface [180]. In
the Wheatstone bridge, its greater sensitivity is paid by a higher excitation source, which
AClimits its operation at lowpower [180]. The effects of changes in the saturation current in
a bipolar transistor (i.e. piezojunction) or in the p and nchannel MOSFET (i.e. piezo FET) current, both related to mechanical stress, have been investigated as a low and ultralowpower alternative [182, 183]. In the latter cases, power can range from a few W down into the nW range, even though the circuit complexity increases significantly [182
30
184]. A number of techniques have been focused on an electronic interface for improving the overall performance of the sensor, including power consumption. A simple alternative, the socalled “active bridge”, is based on the use of a current source for both biasing the gauge and amplifying the small output signal, allowing lowvoltage operation and a consumption of only a few hundred µW [185, 186]. Moreover, interfaces with automatic compensation such as autozero circuits, chopper circuits and dynamic elementmatching
T circuits have also been investigated as lowvoltage, lowpower integrated systems [180]. P Integrated circuit technology offers the enormous advantages of combining both the I micromachined transducer and the acquisition electronic unit in a monolithic device. Figure R 19 shows a classical CMOS differential configuration used to amplify the output of onC Silicon Wheatstone Bridge. A few representative characteristics of an integrated CMOS S amplifier are reported in Table 8, as found in literature for pressure sensors. U Alternative approaches have been more recently investigated using currentmode bridges
which exploit the development of stable current sources and the second generation of
AN current conveyors (CCII) [192, 193]. A currentconveyorbased interface offers M advantages for the output signal (current) allowing us to disregard the effect of the
relatively long wires used, and also enabling the evaluation of up to 5decade electric resistant variations [194196]. The concept of voltage/currentcontrolled negative
D resistances, also called Negative Impedance Converters (NICs), has come back into vogue
because they grant low resistances in current sensing. In particular, the implementation of
E a negative resistance does not require extra temperature monitoring because it makes the T output voltage insensitive to temperature [197, 198]. The literature reviewed in this section P has been focused on the front-end interface that represents one of the core components of E a complete device, which usually includes analogtodigital conversion, signal processing, C and communication modules. The latter should also exploit techniques to minimize the Coverall energy consumption, reducing the constraints on power supply with the aim of Aachieving higher efficiency in practical applications.
9. Discussion and Conclusion
31
The survey of the most recent developments in piezoresistive sensors cannot leave out the technological contexts within which they have been developed, and researchers have faced various challenges in this area. In spite of the fact that more than 150 years have passed since the first article on piezoresistivity appeared, and that much progress has been made in the field of integrated, flexible and even wearable piezoresistive sensors, some common points remain challenging.
T After the first wave of metallic piezoresistive sensors appeared, it was clear to researchers P that one of the main drawbacks was that undesirable physicochemical and environmental I effects (e.g. thermal oxidation and chemical corrosion) degraded the stability of the sensors R over time [99]. In order to overcome these problems, investigations began in the 1980s on C nanomaterialbased (e.g. zinc oxide nanowires) strain gauges, even though in some cases S it was observed that their conductivity decreased with an increase in strain, limiting the use
of these nanowires exclusively to lowstrain applications [199]. Siliconbased nanowires,
U especially ptype, have also been widely investigated for piezoresistive sensing N applications because they exhibit a very fine piezoresistive sensitivity (known as Giant A Piezoresistance) as compared to bulk silicon, and they have been used mostly in M mechanical sensing [200204]. So the power of integratedcircuit technology made way
for the fabrication of nanostructured semiconductor devices for the most varied applications, ranging from the evaluation of the contractile force of cardiomyocytes using
D a cantilever with a resolution of less than 0.1 nN, to the use of a gyroscope based on E piezoresisistive nanosensing for vestibular implant systems having the main advantage of T lowvoltage operation [205, 106]. In the same period of time, the revolution of sensors P fabricated on flexible substrates came about simultaneously with the birth of flexible circuit E technology which was crucial for innovative device fabrication methods [207]. Polymer C based MEMS technology is very flexible, highly compatible with biological systems and
lowcost [208]. Many polymeric materials have been adopted for MEMS applications such
ACas SU8, polyimide, PDMS, PMMA and Parylene to name only a few. The gauge factor was one of the key parameters for the classification of piezoresistive sensors. For instance, a GF of less than 10 identifies metal transducers while semiconductors exhibit a gauge factor of up to 200. The growing demand for mechanical flexibility due to the development of wearable electronics has led an ample use of polymer
32
based conductive composites in sensing applications. This has had its pros and cons. For example, the increase in the use of polymer composites has upset the gaugefactorbased classification system. On the other hand, it has opened the doors to the investigation of materials with giant GFs (from GF <1 to ~ 103 or even greater), which allow new perspectives of application [73, 209, 210].
This review of the literature has highlighted the fact that piezoresistivity continues to
T remain one the most widespread phenomena for the design and fabrication of sensors for P robotics and related fields. Although technology has made great strides forward, sensor I design has remained anchored to the technological dogmas of the mid1900s. Certainly, R the advent of composite materials with their excellent characteristics has allowed C researchers to overcome some problems related to the use of semiconductors and metals S (see Fig.20), but other aspects require further investigation (e.g. stability and
reproducibility) [211]. Table VIII shows some of the representative piezoresistive sensors
U that have been reviewed, the main physical, electric and metrological characteristics of N which could be useful for a qualitative and quantitative comparison. A Apart from the variety of fields in which piezoresistive sensors are successfully M employed, the challenge remains in robotic tactilesensor manufacturing. Piezoelectric and
capacitive sensors are the most recognized competitors of piezoresistors. On the basis of the bioinspired capabilities of humanoids, a distinction should be made between
D piezoresistive and capacitive transducers with respect to piezoelectric transducers. “....the E human sense of touch can be the starting point....” [4]. Although outstanding progress has T been made in the field of piezoresistive tactile sensors, the piezoelectric effect seems to be P the best compromise for artificial tactile perception because of its strict similarity to the E mechanoreceptors of biosystems: that is, Pressure difference = Current generation [120, C 212, 213]. On the other hand, in reference to the electric nature of piezoelectricity and
piezoresistivity, the former doesn't imply the use of transducer supply voltage, as happens
ACwith active piezoresistive transducers, with enormous advantages in terms of dimension,
circuit complexity, and power consumption, at least as far as humanoid artificial touch goes. However, a comprehensive approach results necessary to reduce power consumption in the W range, which is a practical limit for most portable applications (e.g. biomedical) [214]. Even though the fragility of semiconductor strain gauges is a limiting factor in
33
robotic end-effectors, their superiority and reliability remains unquestionable in many industrial and research fields.
MANUSCRIPT ACCEPTED
34
References
[1] R.D. Howe, Tactile sensing and control of robotic manipulation, Advanced Robotics, 8:3 (2010) 245 261.
[2] J. Tao, X. Yu, Hair flow sensors: from bioinspiration to biomimicking—a review, Smart Materials and Structures, 21 (2012) 123.
[3] A.S. Fiorillo, A Piezoresistive Tactile Sensor, IEEE Transactions on Instrumentation and Measurement, 46:1 (1997) 1517.
T [4] R.S. Dahiya, G. Metta, M. Valle, G. Sandini, Tactile sensing: from humans to humanoids, IEEE P Transactions on Robotics, 26 (2010) 120. I [5] M.R. Cutkosky, R.D. Howe, W.R. Provancher, Force and Tactile Sensors, In Springer Handbook of R Robotics, Springer, New York, NY, USA, 2008. C [6] H. Yousef, M. Boukallel, K. Althoefer, Tactile sensing for dexterous in hand manipulation in robotics:
A review, Sensors and Actuators A: Physical, 167 (2011)167171.
S [7] A. Damilano, A. Lince, S. Appendino, H.M. A. Hayat, P. Ariano, D. Demarchi, et al., Commercial tactile U sensors for hand exoskeletons: practical considerations for ultralow cost and verylow complexity
readout, IEEE Instrumentation & Measurement Magazine, 19:5 (2016) 4956.
AN [8] A.S. Fiorillo, P. Dario, M. Bergamasco, A sensorized robot gripper, Robotics and Autonomous Systems, M 4:11 (1988) 4955.
[9] P. Dario, D. De Rossi, Tactile sensors and the gripping challenge: Increasing the performance of sensors over a wide range of force is a first step toward robotry that can hold and manipulate objects as humans do, IEEE Spectrum, 22:8 (1985) 4653.
D [10]W. Thomson, On the electrodynamic qualities of metals: Effects of magnetization on the electric E conductivity of nickel and of iron, Proceedings of the Royal Society of London, 8 (1856) 9546550.
[11] J.W. Cookson, Theory of the piezoresistive effect, Physical Review Journal, 47 (1935) 194195.
T [12] C.S. Smith, Piezoresistance effect in germanium and silicon, Physical Review, 94 (1954) 4249. P [13]H.A. Nielsen, From Locomotives to Strain Gages, New York, Vantage Press, 1985. E [14]D.E. Stout, J.E. Sorensen, C. Kelleher, Write Right: Improving Written Communication Skills—Part C Two, Management Accounting Quarterly, 16:4 (2015).
[15] B.S. Massey, I. Kavrak, A Miniature Pressure Transducer, Journal of Scientific Instruments, 43:8 (1966)
AC569571.
[16] E. Stern, Solidstate sensors in process control, Electrical Engineering, 85:3 (1963) 332335. [17]HP. Phan, D.V. Dao, K. Nakamura, S. Dimitrijev, N.T. Nguye, The Piezoresistive Effect of SiC for
MEMS Sensors at High Temperatures: A Review, Journal of Microelectromechanical Systems, 24:6 (2015) 16631677.
35
[18]H. Tomlinson, On the increase in resistance to the passage of an electric current produced on wires by stretching, Proceedings of the Royal Society of London, 25 (1876) 451453.
[19] V.J. Lumelsky, M.S. Shur, S. Wagner, Sensitive skin, IEEE Sensors Journal, 1:1 (2001) 4151. [20]L. Wang, Y. Li, A Review for Conductive Polymer Piezoresistive Composites and a Development of a
Compliant Pressure Transducer, IEEE Transactions on Instrumentation and Measurement, 62: 2 (2013) 495502. [21] J.J. Carr, Sensors and Circuits, Englewood Cliffs: PTR Prentice Hall, 1993.
T [22]M. Traite, W. Welkowitz, R. Downs, Intracardiac Catheter Tip Piezoresistive Pressure Gauge, Review P of Scientific Instruments, 31:9 (1960) 987991. I [23] A.C. Ruge, Gauge, Patent, US 2316975 A, 1943. R [24] T. Chiku and I. Igarashi, Needleshaped pressure transducer, US Patent n. US3550583A, 1970 C [25]H.W. Shirer, Blood Pressure Measuring Methods” IRE Transactions on BioMedical Electronics, 9:2,
(1962) 116125.
S [26]P. Kantrowitz, Transducer Development for the Artificial Heart or Heart Assist Devices, JAES, 17:5 U (1969) 539549.
[27]R.H. Wyatt, A Study of Power Spectra Analysis of Normal Finger Tremors” IEEE Transactions on
AN Biomedical Engineering, BME15:1 (1968). M [28]J.S. Robinson, A.W. Wood, W. Thorp and C.T. Jones, A Possible Advance in Medical Manometry, Brit.
J. Anaesth., 41, (1969) 6469. [29]M. Maiwald, C. Werner, V. Zoellmer, M. Busse, INKtelligent printed strain gauges, Sensors and
Actuators A: Physical, 162, (2010) 198201.
D [30]K. Bethe, The Scope of the Strain Gage Principle, Proceedings. VLSI and Computer Peripherals E COMPEURO 89, Hamburg, Germany, 812 May, 1989. T [31] M.R. Lindeburg, Environmental Engineering Reference Manual, 2nd Edition, Belmont, CA,
Professional Publications, Inc., 2003.
P [32]L. Meyer, A unified rational analysis for gauge factor and crosssensitivity of electricresistance strain E gauges, The Journal of Strain Analysis for Engineering Design, 2 (1967) 324331. C [33] R.C. Weast, CRC Handbook of Chemistry and Physics, 62th Edition, CRC Press, Boca Raton, FL, 1981. C[34]S.E. Stanca, F. Hänschke, G. Zieger, J. Dellith, A. Dellith, A. Ihring, et al., Electroarchitected porous Aplatinum on metallic multijunction nanolayers to optimize their optical properties for infrared sensor
application, Nanotechnology, 29 (2018) 112. [35]R.L. Parker, A. Krinsky, Electrical Resistance Strain Characteristics of Thin Evaporated Metal Films,
Journal of Applied Physics, 34 (1963) 27002708, 1963. [36] W.P. Mason, Crystal Physics of interaction processes, Academic Press, NY, 1966.
36
[37]B.N. Streetman, Solid State Electronic Devices, PrenticeHall, inc, Englewood cliffs, NJ, 2nd Edition, 1980.
[38] S.M. Sze, Physics of semiconductor devices, J. Wiley & Sons, lst ed., N.Y., 1969. [39] W.G. Pfann, Isotropically piezoresistive semiconductor”, Journal of Applied Physics, 33 (1962) 1618
1619. [40] R.S. Okojie, A.A. Ned, A.D. Kurtz, W.N. Carr, Characterization of Highly Doped n and pType 6H
SiC Piezoresistors, IEEE Transactions on Electron Devices, 45:4 (1998) 785790.
T [41]M. Kanaya, J. Takahashi, Y. Fujiwara, A. Moritani, Controlled sublimation growth of single crystalline P 4HSiC and 6HSiC and identification of the polytypes by xray diffraction, Applied Physics Letters, I 58 (1991) 5658. R [42] D. Patranabis, Sensors and Transducers, 2nd ed., New Delhi, PHI Learning Pvt ltd., 2004.
[43] F. Bechstedt, P. Kackell, A. Zywietz, K. Karch, B. Adolph, K. Tenelsen, J. Furthmuller, Polytypism and
C properties of silicon carbide, Physica Status Solidi (b), 202 (1997) 3562. S [44] M. Aryafar, M. Hamedi, M.M. Ganjeh, A Novel Temperature Compensated Piezoresistive Pressure U Sensor, Measurement, 63 (2015) 2529.
[45] M.H. Bao, Micro Mechanical TransducersPressure Sensors, Accelerometers and Gyroscopes, Elsevier
AN B.V., Amsterdam, The Netherlands, 2000. M [46]Q. Wang, J. Ding, W. Wang, Fabrication and temperature coefficient compensation technology of low
cost high temperature pressure sensor, Sensors and Actuators A: Physical, 120 (2005) 468473. [47] Y. Liu, H. Wang, W. Zhao, H. Qin, X. Fang, ThermalPerformance Instability in Piezoresistive Sensors:
Inducement and Improvement, Sensors, 16 (2016) 123.
D [48]Z. Yao, T. Liang, P, Jia, Y, Hong, L. Qi, C. Lei, et al., Passive Resistor Temperature Compensation for E a HighTemperature Piezoresistive Pressure Sensor, Sensors, 16:7 (2016).
[49] D. Hagner, Metal strain gages, in: Tactile sensors far robot and medicine, J. Webster Ed., New York, J.
T Wi1ey & Sons, 7598, 1988. P [50] H.L. Trietley, Transducers in Mechanical and Electronic Design, New York: Marcel Dekker, Inc., 1986. E [51] L.E. Hollander, G.L. Vick, T.J. Diesel, The Piezoresistive Effect and its Applications, Review of C Scientific Instruments. 31:3 (1960) 323327.
[52]P.J. French, A.G.R. Evans, Piezoresistance in polysilicon and its applications to strain gauges, Solid
ACState Electronics, 32:1 (1989) 110.
[53] J.C. Doll, B.L. Pruitt, Piezoresistor Design and Applications, Springer, New York, NY, 2013. [54]R. Taherian, Development of an Equation to Model Electrical Conductivity of PolymerBased Carbon
Nanocomposites, Journal of Solid State Science and Technology, 3:6 (2014) M26M38, 2014. [55] F. Lux, Models proposed to explain the electrical conductivity of mixtures made of conductive and
insulating materials, Journal of Materials Science, 28 (1993) 285301.
37
[56] L. Karásek, B. Meissner, S. Asai M. Sumita, Percolation Concept: PolymerFiller Gel Formation, Electrical Conductivity and Dynamic Electrical Properties of CarbonBlackFilled Rubbers, Polymer Journal, 28 (1996) 121126.
[57]M.H. AlSaleh, U. Sundarara, A review of vapor grown carbon nanofiber/polymer conductive composites, Carbon, 47, 222, 2009.
[58]R.A. Russell, An imaging force sensor for robotics applications, National Conference on Robotics, Melbourne, (1984) 123127.
T [59]W. Zhang, J. Suhr, N. Koratkar, Carbon nanotube/polycarbonate composites as multifunctional strain P sensors, J. Nanosci. Nanotechnol., 6 (2006) 960964. I [60]G.T. Pham, Y.B. Park, Z. Liang, C. Zhang, B. Wang, Processing and modeling of conductive R thermoplastic/carbon nanotube films for strain sensing”, Compos. Part B, 39 (2008) 209216.
[61] J.G: Rocha, A.J. Paleo, F.W.J. van Hattum, S. LancerosMendez, PolypropyleneCarbon Nanofiber
C Composites as StrainGauge Sensor, IEEE Sensors Journal, 13:7 (2013) 26032609. S [62]K.J. Loh, J.P. Lynch, B.S. Shim, N.A. Kotov, Tailoring piezoresistive sensitivity of multilayer carbon U nanotube composite strain sensors, J. Intell. Mater. Syst. Struct., 19 (2008) 747764.
[63]T. Yasuoka, Y. Shimamura, A. Todoroki, Electrical resistance change under strain of CNF/flexible
N epoxy composite, Adv. Compos. Mater., 19 (2010) 123138. A [64]N. Wang, X. Zhuoyan, P. Zhan, K. Dai, G. Zheng, C. Liu, et al., A tunable strain sensor based on a M carbon nanotubes/electrospun polyamide 6 conductive nanofibrous network embedded into poly(vinyl
alcohol) with selfdiagnosis capabilities, Journal of Materials Chemistry C, 5 (2017) 44084418. [65]V. Singh, D. Joung, L. Zhai, S. Das, S.I. Khondaker, S. Seal, Graphene based materials: past, present
D and future, Prog. Mater. Sci., 56:8 (2011) 11781271. E [66]K.S. Novoselov, A.K. Geim, S.V. Morozov, D. Jiang, Y. Zhang, S.V. Dubonos, et al., Electric field
effect in atomically thin carbon films, Science, 306 (2004) 666669.
T [67] A.K. Geim, K.S. Novoselov, The rise of graphene, Nature Materials, 6:3 (2004) 183191. P [68]C. Lee, X. Wei, J.W. Kysar, J. Hone, Measurement of the elastic properties and intrinsic strength of E monolayer graphene, Science, 321, (2008) 385388. C [69]J.H. Chen, C. Jang, S. Xiao, M. Ishigami, M.S. Fuhrer, Intrinsic and extrinsic performance limits of
graphene devices on SiO2, Nature Nanotechnology, 3:4 (2008) 206209.
C[70]M.B. Coskun, L. Qiu, Md. S. Arefin, A. Neild, M. Yuce, D. Li, et al., Detecting Subtle Vibrations Using AGrapheneBased Cellular Elastomers, ACS Appl. Mater. Interfaces, 9 (2017) 1134511349.
[71] L. Qiu, J.Z. Liu, S.L.Y. Chang, Y. Wu, D. Li, Biomimetic superelastic graphenebased cellular monoliths, Nature Communications, 3 (2012) article number 1241.
[72]A. Rinaldi, A. Tamburrano, M. Fortunato, M.S. Sarto, A Flexible and Highly Sensitive Pressure Sensor Based on a PDMS Foam Coated with Graphene Nanoplatelets, Sensors, 16, (2016) 2148.
38
[73]X. Ye, Z. Yuan, H. Tai, W. Li, X. Dua, Y. Jianga, A wearable and highly sensitive strain sensor based on a polyethyleniminerGO layered nanocomposite thin film, Journal of Materials Chemistry C, 117:1 (2005) 5061.
[74] S. Iijima, Helical microtubules of graphitic carbon, Nature, 354 (1991) 5658. [75] S. Iijima, T. Ichihashi, Singleshell carbon nanotubes of 1nm diameter, Nature, (1993) 363, 603605. [76]D. Bethune, C. Klang, M. De Vries, G. Gorman, R. Savoy, J. Vazquez, et al., Cobaltcatalysed growth
of carbon nanotubes with singleatomiclayer walls, Nature, 363, (1993) 605607.
T [77]H. Chen, L. Miao Z. Su, Y. Song, M. Han, X. Chen, et al., Fingertipinspired electronic skin based on P triboelectric sliding sensing and porous piezoresistive pressure detection, Nano Energy, 40 (2017) 65 I 72. R [78]T. Yamada, Y. Hayamizu, Y. Yamamoto, Y. Yomogida, A.I. Najafabadi, D.N. Futaba, et al., A
stretchable carbon nanotube strain sensor for humanmotion detection, Nature Nanotechnology, 6 (2011)
C 296301. S [79]D. Cho, J. Park, J. Kim, T. Kim, J. Kim, I. Park, et al., Three Dimensionally Continuous Conductive U Nanostructure for Highly Sensitive and Stretchable Strain Sensor, Applied Materials and Interfaces,
9:20, (2017) 1736917378.
N [80]B. Philip, J.K. Abraham, A. Chandrasekhar, V.K Varadan, Carbon nanotube/PMMA composite thin A films for gassensing applications, Smart Materials and Structures, 12:6 (2003) 935939.
[81] J. Li, Y. Lu, M. Meyyappan, Nano Chemical Sensors with PolymerCoated Carbon Nanotubes, IEEE
M Sensors Journal, 6:2 (2006) 10471051.
[82] S. Shang, Y. Yue, X. Wang, Piezoresistive strain sensing of carbon black /silicone composites above
D percolation threshold, Review of Scientific Instruments, 87:12 (2016) 1239105. E [83]B. Wang, B.K. Lee, M.J. Kwak, D.W. Lee “Graphene/polydimethylsiloxane nanocomposite strain
sensor, Review of Scientific Instruments, 84 (2013) 1050054,.
T [84]C. Lee, L. Jug, E. Meng, High strain biocompatible polydimethylsiloxanebased conductive graphene P and multiwalled carbon nanotube nanocomposite strain sensors, Applied Physics Letters, 102 (2013) E 1835115.
[85] T. Gurunathan, C.R.K. Rao, R. Narayan, K.V.S.N. Raju, Polyurethane conductive blends and
C composites: Synthesis and applications perspective, J. Mater Sci., 48:1 (2013) 6780. C[86]P. Zhao, Y. Luo, J. Yang, D. He, L. Kong, P. Zheng, et al., Electrically conductive graphenefilled Apolymer composites with well organized threedimensional microstructure, Mater Lett., 121 (2014) 74
77. [87] W. Xiaodong, H. Yangyang, Z. Xinxing, L. Canhui, Spirally Structured Conductive Composites for
Highly Stretchable, Robust Conductors and Sensors, ACS Applied Materials & Interfaces, 9:27 (2017) 2300723016.
39
[88]H. Hu, X Wang, J Wang, L Wan, F Liu, H Zheng, et al., Preparation and properties of graphene nanosheetspolystyrene nanocomposites via in situ emulsion polymerization, Chemical Physics Letters, 484 (2010) 247253.
[89]F. Du, J.E. Fischer, K.I. Winey, Effect of nanotube alignment on percolation conductivity in carbon nanotube/polymer composites, Physical Review B, 72:12 (2005) 1214044.
[90]N Jović, D Dudić, A Montone, Mv Antisari, M Mitrić, V Djoković, Temperature dependence of the electrical conductivity of epoxy/expanded graphite nanosheet composites, Scripta Materialia, 58, (2008)
T 846849. P [91] W. Zheng, S.C. Wong, Electrical conductivity and dielectric properties of PMMA/expanded graphite I composites, Compos. Sci. Technol., 63 (2003) 225235, 2003. R [92]H.B. Zhang, W.G. Zheng, Q. Yan, Y. Yang, J.W. Wang, Z.H. Lu, et al. “Electrically conductive
polyethylene terephthalate/graphene nanocomposites prepared by melt compounding, Polymer, 51
C (2010) 11911196. S [93]M. Ha, S. Lim, J. Park, D.S. Um, Y. Lee, H. Ko, Bioinspired interlocked and hierarchical design of ZnO
nanowire arrays for static and dynamic pressuresensitive electronic skins, Adv. Funct. Mater., 25 (2015)
U 28412849. N [94] L.W. Yap, S. Gong, Y. Tang, Y. Zhu, W. Cheng, Soft piezoresistive pressure sensing matrix from copper A nanowires composite aerogel, Science Bullettin, 61:20 (2016) 16241630. M [95]C. Pang, GY Lee, TI Kim, S.M, Kim, H.N. Kim, SH Ahn, et al., A flexible and highly sensitive
straingauge sensor using reversible interlocking of nanofibres, Nature Materials, 11 (2012) 795801. [96] H.P. Wang, D. Zhou, J. Cao, R. Lindeke, A SkinLike Pressure Sensor Array Based on Silver Nanowires
D and Conductive Elastomer, Conference on Smart Materials, Adaptive Structures and Intelligent Systems,
Snowbird, Utah, USA, 1618 September, 2013.
E [97] S. Gong, W. Schwalb, Y. Wang, Y. Chen, Y. Tang, J. Si, et al., A wearable and highly sensitive pressure T sensor with ultrathin gold nanowires, Nature Communications, 5 (2014) article number 3132. P [98] Y. Zang, F. Zhang, C. Di, D. Zhu, Advances of flexible pressure sensors toward artificial intelligence E and health care applications, Materials Horizons, 2 (2015) 140156.
[99]C. Celle, A. Cabos, T. Fontecave, B. Laguitton, A. Beneyad, L. Guettaz, et al., Oxidation of copper
C nanowire based transparent electrodes in ambient conditions and their stabilization by encapsulation: CApplication to transparent film heaters, Nanotechnology, 29:8 (2018). A[100] C. Canali, D. Malvasi, B. Morten, M. Prudenziati, A. Taroni, Piezoresistive effects in thickfilm
resistors, Journal of Applied Physics, 51:6 (1980) 32823287. [101] K.J. Puttlitz, P.A. Totta. “Area Array Interconnection Handbook, Springer Science + Business Media,
New York, 2001.
40
[102] X. Chen, Z. Zhang, S. Liu, Thick film resistors on alumina substrate as sensing elements, 13th International Conference on Electronic Packaging Technology & High Density Packaging, Guilin, China, 1316 Aug., 2012.
[103] N.M. White, J.D. Turner, Thickfilm Sensors: Past, Present and Future, Meas. Sci. Technol., 8 (1997) 120.
[104] M. Prudentiziati, Handbook of Sensors and Actuators: Thickfilms Sensors, 1, Ed. Elsevier, 1994, [105] B.L. de Lima, A.N. Rodrigues da Silva, N. Morimoto, A Proposed Process to Fabricate Strain Gauge
T Directly Over the Sensor Substrate, ECS Trans., 4:1 (2007) 123130. P [106] D. Crescini, Load cell for dynamic force measurements: An example in ThickFilm Technology, I IEEE International Conference on Instrumentation and Measurement Technology, Graz, Austria, 1316 R May, 2012.
[107] S. Guo, M. Miao, R. Fang, D. Hu, Y. Jin, A thick film accelerometer based on LTCCtechnology,
C 13th International Conference on Electronic Packaging Technology & High Density Packaging, Guilin, S China, 1316 Aug., 2012. U [108] S.A.A. Jabir and N.K. Gupta, ThickFilm Ceramic Strain Sensors for Structural Health Monitoring,
IEEE Transactions on Instrumentation and Measurement, 60:11 (2011) 36693676.
N [109] L.G. Occhipinti, E. Fontana, S. Smerzi, E. Spoto, M. Renna, A. Romano, et al., Flexible and A conformable strain gauges for smart pressure sensors systems: Static and dynamic characterization, 15th
IEEE International Conference on Nanotechnology, Rome, Italy, 2730 July, 2015.
M [110] H. Tu, X. Chen, X. Feng, and Y. Xu, A postCMOS compatible smart yarn technology based on SOI
wafers, Sensors and Actuators A: Physical, 233 (2015) 397404.
D [111] N. Klejwa, N. Harjee, R. Kwon, S.M. Coulthard, B.L. Pruitt, Transparent SU8 ThreeAxis Micro
Strain Gauge Force Sensing Pillar Arrays for Biological Applications, International Conference on
E SolidState Sensors, Actuators and Microsystems, Lyon, France, 1014 June, 2007. T [112] H.J. Xian, C.R. Cao, J.A. Shi, X.S. Zhu, Y.C. Hu, Y.F. Huang, et al., Flexible strain sensors with high P performance based on metallic glass thin film, Appl. Phys. Lett., 111 (2017) 1219065. E [113] J. Engel, J. Chen, Z. Fan, C. Liu, Polymer micromachined multimodal tactile sensors, Sensors and
Actuators A: Physical, 117:1 (2005) 5061.
C [114] J. Engel, J. Chen, C. Liu, Strain sensitivity enhancement of thin metal film strain gauges on polymer Cmicroscale structures, Applied Physics Letters, 89:22 (2006). A[115] J.A. Rogers, T. Someya, Y. Huang, Materials and Mechanics for Stretchable Electronics, Science,
327 (2010) 16031606. [116] D.H. Kim and J.A. Rogers, Stretchable Electronics: Materials Strategies and Devices, Advanced
Materials, 20 (2008) 48874892.
41
[117] M.I. Tiwana, S.J. Redmond, N.H. Lovell, A review of tactile sensing technologies with applications in biomedical engineering, Sensors and Actuators A: Physical, 179 (2012) 1731.
[118] V. Bicchi and V. Kumar, Robotic grasping and contact: A review, International Conference on Robotics and Automation (ICRA), 1, 348353, San Francisco, USA, 2428 April, 2000.
[119] F. VidalVerdú, O. OballePeinado, J.A. SánchezDurán, J. CastellanosRamos, R. Navas González, Three realizations and comparison of hardware for piezoresistive tactile sensors, Sensors, 11:3 (2011) 32493266.
T [120] C. Lucarotti, C.M. Oddo, N Vitiello, M.C. Carrozza, Synthetic and BioArtificial Tactile Sensing: A P Review, Sensors, 13:2 (2013) 14351466. I [121] Z. Liao, W. Liu, C. Zhang, Y. Zhang, X. Wang, X. Li, A tactile sensor translating texture and sliding R motion information into electrical pulses, Nanoscale, 7:24 (2015) 1080110806.
[122] A. Charalambides and S. Bergbreite, A novel allelastomer MEMS tactile sensor for high dynamic
C range shear and normal force sensing, J. Micromech. Microeng., 25 (2015) 0950099. S [123] L.D. Harmon, Automated Tactile Sensing, The International Journal of Robotics Research, 1:2 U (1982) 332.
[124] S. Stassi, V. Cauda, G. Canavese, C.F. Pirri, Flexible Tactile Sensing Based on Piezoresistive
N Composites: A Review, Sensors, 14:3 (2014) 52965332. A [125] A. Caiti, G. Canepa, D. De Rossi, F. Germagnoli, G. Magenes, T. Parisini, Towards the realization
of an artificial tactile system: Fineform discrimination by a tensorial tactile sensor array and neural
M inversion algorithms”, IEEE Transactions on Systems, Man, Cybernetics, 25 (1995) 933946.
[126] H.N. Norton, Handbook of Transducers, Englewood Cliffs: Prentice- Hall, Inc., 1989.
D [127] K. Noda, K. Hoshino, K. Matsumoto; and I. Shimoyama, A shear stress sensor for tactile sensing with E the piezoresistive cantilever standing in elastic material, Sensors and Actuators A: Physical, 127 (2006)
295301.
T [128] T. Takeshita, T. Kobayashi, R. Takei, T. Itoh, S. Takamatsu, Softrubberpackaged Pb(Zr,Ti)O3 P MEMS touch sensors for humanmachine interface applications, Japanese Journal of Applied Physics, E 56 (2017) 04CC040105.
[129] T. Okatani, H. Takahashi, K. Noda, T. Takahata, K. Matsumoto, I. Shimoyama, A Tactile Sensor
C Using Piezoresistive Beams for Detection of the Coefficient of Static Friction, Sensors, 16 (2016) 718. C[130] J. Zhou, W. Rong, L. Wang, P. Gao, L. Sun, A selfdecoupling piezoresistive sensor for measuring Amicroforce in horizontal and vertical directions, Journal of Micromechanics and Microengineering, 26:9
(2016) 09501910. [131] E. Laukhina, R. Pfattner, L.R. Ferreras, S. Galli, M. MasTorrent, N. Masciocchi, et al., Ultrasensitive
Piezoresistive Allorganic Flexible Thin Films, Adv. Mater., 22:9 (2010) 977981.
42
[132] C. Connolly, Switches and pressure sensors benefit from novel composite material, Sensor Review, 24:3 (2004) 261264.
[133] R. Walker, Developments in dextrous hands for advanced robotic applications, 10th Int. Symp. Robot. App., Seville, Spain, 28 June 1 July 2004.
[134] J. Engel, J. Chen and C. Liu, Development of polyimide flexible tactile sensor skin, J. Micromech. Microeng., 13 (2003) 359366.
[135] C. Stampfer, A. Jungen, R. Linderman, D. Obergfell, S. Roth, C. Hierold, NanoElectromechanical
T Displacement Sensing Based on SingleWalled Carbon Nanotubes, Nano Letters, 6:7 (2006) 1449 P 1453. I [136] A.J. Brook, S.J. Bending, J. Pinto, A. Oral, D. Ritchie, H. Beere, et al., Micromachined IIIV R cantilevers for AFMtracking scanning Hall probe microscopy, J. Micromech. Microeng., 3 (2003) 124
128.
C [137] Y. Penga, S. Itoa, Y. Shimizua, T. Azumaa, W. Gaoa, E. Niwa, A CrN thin film displacement sensor S for precision positioning of a microstage, Sensors and Actuators A: Physical, 211 (2014) 8997. U [138] J.A. Harley, T.W. Kenny, 1/f noise considerations for the design and process optimization of
piezoresistive cantilevers, Journal of Microelectromechanical Systems, 9 (2000) 226235.
N [139] M. Rouff, Z. Lakhdari, M. Cotsaftis, S. Konieczka, Dynamical and thermal modelling of creep and A relaxation for force and weight sensors, Mechatronics, 13 (2003) 7784.
[140] R. Boynton ,Precise Measurement of Mass, 60th Annual Conference of the Society of Allied Weight
M Engineers, Arlington, Texas, May 2123, 2001.
[141] K.N. Bhat, Silicon Micromachined Pressure Sensors, Journal of the Indian Institute of Science, 87:1
D (2007). E [142] R. Bogue, Recent developments in MEMS sensors: A review of applications, markets and
technologies, Sensor Review, 33:4 (2013) 300304.
T [143] K.N. Bhat, M.M. Nayak, MEMS Pressure Sensors: An Overview of Challenges in Technology and P Packaging, Journal of ISSS, 2:1 (2013) 3971. E [144] S.S. Kumar, B.D. Pant, Design principles and considerations for the ideal silicon piezoresistive
pressure sensor: A focused review, Microsystem Technology, 20:7 (2014) 12131247.
C [145] S.S. Kumar, B. D. Pant, Polysilicon thin film piezoresistive pressure microsensor: Design, fabrication Cand characterization, Microsystem Technology, 21:9 (2015) 19491958. A[146] G. Nakatani, MEMS Sensor”, Us Patent US 8,387.459 B2, 2013.
[147] S. Coombs, Smart Skins: Information Processing by Lateral Line Flow Sensors”, Autonomous Robots, 11 (2001) 255261.
43
[148] B. Bathellier, F.G. Barth, J.T. Albert and J.A. Humphrey, Viscositymediated motion coupling between pairs of trichobothria on the leg of the spider Cupiennius Salei”, Journal of Comparative Physiology A, 191:8 (2005) 733746.
[149] S.J. SterbingDAngelo, M. Chadha, K.L. Marshall, C.F. Moss, Functional role of airflowsensing hairs on the bat wing”, Journal of Neurophysiology, 117:2 (2017) 705712.
[150] M. Le Masurier, P.G. Gillespie, HairCell Mechanotransduction and Cochlear Amplification”, Neuron, 48 (2005) 403415.
T [151] Z. Fan, J. Chen, J. Zou, D. Bullen, C. Liu and F. Delcomyn, Design and fabrication of artificial lateral P line flow sensors”, Journal of Micromechanics and Microengineering, 12 (2002) 655661. I [152] N. Nguyen, D.L. Jones, Y.C. Yang and C. Liu, Flow vision for autonomous underwater vehicles via R an artificial lateral line”, Journal on Advances in Signal Processing, 2011 (2011) 111.
[153] S. Peleshanko, M.D. Julian, M. Ornatska, M.E. Mc Conney, M.C. LeMieux, N. Chen et al., Hydrogel
C encapsulated microfabricated haircells mimicking fish cupula neuromast”, Advanced Materials, 19 S (2007) 29032909. U [154] Z. Shen, A.G.P. Kottapalli, V. Subramaniam, M. Asadnia, J. Miao, M. Triantafyllou, Biomimetic
Flow Sensors for Biomedical Flow Sensing in Intravenous Tubes”, IEEE Sensors Conference, Orlando,
N Florida, USA, 30 October3 November 2016. A [155] Y.H. Wang, C.Y. Lee and C.M. Chiang, A MEMSbased Air Flow Sensor with a Freestanding
Microcantiveler Structure”, Sensors, 7 (2007) 23892401.
M [156] S. Zhang, L. Lou, C. Lee. “Piezoresistive silicon nanowire based nanoelectromechanical system
cantilever air flow sensor”, Applied Physics Letters, 100:2 (2012) 023111023113.
D [157] A.R. Aiyar, C. Song, S.H. Kim, M.G. Allen, An allpolymer airflow sensor using a piezoresistive
composite elastomer”, Smart Materials and Structures, 18 (2009) 1150039.
E [158] C. Jacq, B. Lüthi, Th. Maeder, O. Lambercy, R. Gassert, P. Ryser. “Thickfilm multiDOF T force/torque sensor for wrist rehabilitation”, Sensors and Actuators A: Physical, 168 (2010) 361366. P [159] J. Caroline, T. Maeder, S. Emery, M. Simoncini, E. Meurville, P. Ryser. “Investigation of Polymer E ThickFilm Piezoresistors for Medical Wrist Rehabilitation and Artificial Knee Load Sensors”, Procedia
Engineering, 87 (2014) 11941197.
C [160] H. Khan, M. DImperio, F. Cannella, D.G. Caldwell, A. Cuschieri and C. Semini. “Towards Scalable CStrain GaugeBased Joint Torque Sensors”, Sensors, 17 (2017) 1905, 117. A[161] L.M. Roylance, J.B. Angell. "A batchfabricated silicon accelerometer, IEEE Transaction on
Electron Devices, 26:12 (1979) 19111917. [162] J. Fraden. Handbook of Modern Sensors; Physics, Design, Applications, Fourth Edition, Springer
Press, 2010.
44
[163] P. Dong, X. Li, Y. Wang, S. Feng. “An Axialbeam Piezoresistive Accelerometer for Highperformance Crash Detection of Automotive Industry”, IEEE Sensors Conference, Daegu, South Korea, 2225 October 2016.
[164] S. Chitta, P. Vemaza, R. Geykhman. and D.D. Lee. “Proprioceptive localization for a quadrupedal robot on known terrain”, IEEE International Conference on Robotics and Automation, Roma, Italy, 10 14 April, 2007.
[165] P.H. Mansur, L.K. Cury, A.O. Andrade, A.A. Pereira, G.A. Miotto, A.B. Soares, E.L. Naves. “A
T review on techniques for tremor recording and quantification”, Critical Reviews in Biomedical P Engineering, 35:5 (2007) 343362. I [166] S. Biswas, A.K. Gogoi. “Design of a Piezoresistive Microaccelerometer with High Sensitivity for R Medical Diagnostic”, In: A. Konkani, R. Bera, S. Paul (eds), Advances in Systems, Control and
Automation. Lecture Notes in Electrical Engineering, 442, Springer, Singapore, 2018.
C [167] S. Franco, Design with Operational Amplifier and Analog Integrated Circuits, India: TMH 9197, S 2002.
[168] S. Gift and B. Maundy, Strain Gauge Amplifier Circuits, IEEE Transactions on Instrumentation and
U Measurement, 62:4 (2013) 693700. N [169] D.J. Yonce, P.P. Bey, T.L. Fare, A DC Autonulling Bridge for RealTime Resistance Measurement, A IEEE Transactions on Circuits and Systems I: Fundamental Theory and Applications, 47:3 (2000) 273 M 278.
[170] E. Farshidi, A LowVoltage CurrentMode Wheatstone Bridge using CMOS Transistors;” International Journal of Electrical and Electronics Engineering, 5:1 (2011) 3842.
D [171] S. Gift and B. Maundy, New configuration for the measurement of small resistance changes”, IEEE Trans. Circuits and SystemsII: Express Brief, 53:3 (2006) 178182.
E [172] I.F. Akyildiz, W. Su, Y. Sankarasubramaniam, E. Cayirci, A survey on sensor networks, IEEE T Communications Magazine, 40:8 (2002), 102114. P [173] I. Clausen, T. Glott, Development of Clinically Relevant Implantable Pressure Sensors: Perspectives E and Challenges, Sensors 14 (2014) 1768617702.
[174] K. Arshak, G. Lyons, L. Cavanagh, S. Clifford, Front end signal conditioning used for resistance
C based sensors in electronic nose systems: a review, Sensor Review, 23:3 (2003) 230241 C[175] A. Loui, T.V. Ratto, T.S. Wilson, S.K. McCall, E.V. Mukerjee, A.H. Love, B.R. Hart, Chemical vapor Adiscrimination using a compact and lowpower array of piezoresistive microcantilevers, Analyst, 133:5
(2008) 608615. [176] J.D. Adams, G. Parrott, C. Bauer, T. Sant, L. Manning, M. Jones, B. Rogers, Nanowatt chemical
vapor detection with a selfsensing, piezoelectric microcantilever array, Applied Physics Letters, 83:16 (2003) 34283430.
45
[177] M. Crego Calama, S. Brongersma, D. Karabacak, M. Van Bavel, A low power integrated electronic nose system, Sensor Review, 32:1 (2012) 7276
[178] P.D. Harris, W.M. Arnold, M.K. Andrews, A.C. Partridge, Resistance characteristics of conducting polymer films used in gas sensors, Sensors and Actuators B: Chemical, 42 (1997) 177184.
[179] M.A. Cullinan, R.M. Panas, C.M. Di Biasio, M.L. Culpepper, Scaling electromechanical sensors down to the nanoscale, Sensors and Actuators A: Physical, 187 (2012) 162173.
[180] Falconi, C. Di Natale, A. DAmico, M. Faccio, Electronic interface for the accurate readout of
T resistive sensors in low voltagelow power integrated systems, Sensors and Actuators A: Physical, 117 P (2005) 121126. I [181] A. Thanachayanont, S. Sangtong,Low Voltage Current Sensing CMOS Interface Circuit for R Piezo Resistive Pressure Sensor, ETRI Journal, 29:1 (2007) 7078.
[182] J.F. Creemer, F. Fruett, G.C.M. Meijer, P.J. French, The piezojunction effect in silicon sensors and
C circuits and its relation to piezoresistance, IEEE Sensors Journal, 1 (2001) 98108. S [183] M. Doelle, C. Peters, P. Ruther, O. Paul, PiezoFET StressSensor Arrays for WireBonding U Characterization, Journal of Microelectromechanical Systems, 15:1 (2006) 120130.
[184] R.G. Beck, M.A. Eriksson, M.A. Topinka, R.M. Westervelt, K.D. Maranowski, A.C. Gossard,
N GaAs/AlGaAs self-sensing cantilevers for low temperature scanning probe microscopy, Applied Physics A Letters 73:8 (1998) 11491151.
[185] E.M. Boujamaa, B. Alandry, S. Hacine, L. Latorre, F. Mailly, P. Nouet, A Low Power Interface
M Circuit for Resistive Sensors with Digital Offset Compensation, IEEE International Symposium on
Circuits and Systems, (2010).
D [186] N. Dumas, S. Hacine, F. Mailly, L. Latorre, P. Nouet, A tracking converter for resistive sensors based
on a feedback active bridge, IEEE 9th International on New Circuits and Systems Conference, (2011)
E 458461. T [187] V. Garcia, F. Fruett, A mechanicalstress sensitive differential amplifier, Sensors and Actuators A: P Physical, 132 (2006) 813. E [188] G. de Oliveira Coraucci, F. Fruett “Study, design, microfabrication and characterization of a new
CMOS compatible multiterminal pressure sensor with enhanced sensitivity, Sensors and Actuators A:
C Physical, 165 (2011) 4353. C[189] P. Gonzalez, M. Rakowski, D. San Segundo, S. Severi, K. de Meyer, A. Witvrouw, CMOSIntegrated APolySiGe Piezoresistive Pressure Sensor, IEEE Electron Device Letters, 33:8 (2012) 12041206.
[190] A. Donida and D. Barrettino, A LowPower Interface Circuit for Piezoresistive Transducers, IEEE International Conference on Instrumentation and Measurement Technology, Pisa, Italy, 1114 May, 2015.
46
[191] Y. Deimerly, Towards ultracompact inertial platforms based on piezoresistive nanogauges: focus on cointegration issues, Ph.D: dissertation, Electronics Université ParisEst, 2013.
[192] N.A. Gilda, S. Nag, S. Patil, M.S. Baghini, D.K. Sharma, V.R. Rao, Current Excitation Method for ΔR Measurement in PiezoResistive Sensors with a 0.3ppm Resolution, IEEE Transactions on Instrumentation and Measurement, 61:3 (2012) 767774.
[193] A.S. Sedra and G. W. Roberts, Current conveyor theory and practice, In: Analogue IC Design: The Current Mode Approach, C. Toumazou, F. J. Lidgey, D. G. Haigh, Eds. London, U.K.: Peter Peregrinus,
T Ltd., 1990. P [194] J. Samitier, M. PuigVidal, S.A. Bota, C. Rubio, S.K. Siskos, T. Laopoulos, A CurrentMode I Interface Circuit for a Piezoresistive Pressure Sensor, IEEE Transactions on Instrumentation and R Measurement, 47:3 (1998).
[195] G. Ferri, V. Stornelli, M. Fragnoli, An integrated improved CCII topology for resistive sensor
C application, Analog Integr. Circ. Sig. Process., 48 (2006) 247250. S [196] A. De Marcellis, G. Ferri, P. Mantenuto, Analog Wheatstone bridgebased automatic interface for
grounded and floating widerange resistive sensors, Sensors and Actuators B: Chemical, 187 (2013)
U 371378. N [197] A.J. LopezMartin, M. Zuza, A. Carlosena, Analysis of a NIC as a temperature compensator for A bridge sensors, IEEE Transactions on Instrumentation and Measurement, 52:4 (2003) 10681072. M [198] A.J. LopezMartin, A. Carlosena, LowCost Analog Interface Circuit for Resistive Bridge Sensors ,
13th International Symposium on Communications and Information Technologies, Surat Thani, Thailand, 46 Sept., 2013.
D [199] S. Yang, L. Wang, X. Tian, Z. Xu, W. Wang, X. Bai, et al., The Piezotronic Effect of Zinc Oxide Nanowires Studied by insitu TEM, Adv. Mater., 24 (2012) 46764682.
E [200] T. Toriyama, D. Funai, S. Sugiyama, Piezoresistance measurement on single crystal silicon T nanowires, Journal of Applied Physics, 93:1 (2003) 561565. P [201] D.V. Dao, T. Toriyama, S. Sugiyama, Noise and Frequency Analyses of a Miniaturized 3DOF E Accelerometer Utilizing Silicon Nanowire Piezoresistors, IEEE Sensors Conference, Vienna, Austria,
2427 Oct., 2004.
C [202] T. Toriyama, Y. Tanimoto, S. Sugiyama. Single crystal silicon nanowire piezoresistors for Cmechanical sensors, Journal of Microelectromechanical Systems, 11:5 (2002) 605611. A[203] S. Vetrivel, R. Mathew, R. Sankar, Design and optimization of a doubly clamped piezoresistive
acceleration sensor with an integrated silicon nanowire piezoresistor, Microsystem Technologies, 23:8 (2017) 35253536. [204] M. Messina, J. Njuguna, V. Dariol, C. Pace, G. Angeletti, Design and Simulation of a Novel Biomechanic Piezoresistive Sensor with Silicon Nanowires, IEEE/ASME Transactions on Mechatronics, 18:3 (2013) 12011210.
47
[205] K. Matsudaira, TV Nguyen, K.H. Shoji, T. Tsukagoshi, T. Takahata, I. Shimoyama, MEMS piezoresistive cantilever for the direct measurement of cardiomyocyte contractile force, Journal of Micromechanics and Microengineering, 27:10 (2017).
[206] S. Dellea, A. Longoni, G. Langfelder, A. Nikas, O. Leman, J. Hauer, et al., A comprehensive study of NEMSbased piezoresistive gyroscopes for vestibular implant systems, IEEE International Symposium on Inertial Sensors and Systems, Kauai, HI, USA, 2730 March 2017.
[207] Y.S. Rim, S.H. Bae, H. Chen, N. De Marco, Y. Yang. “Recent Progress in Materials and Devices
T toward Printable and Flexible Sensors, Adv. Mater., 28 (2016) 44154440. P [208] B. Kim and E. Meng, Review of polymer MEMS micromachining, Journal of Micromechanics and I Microengineering, 26:1 (2016) 01300121. R [209] X. Li, R. Zhang, W. Yu, K. Wang, J. Wei, D. Wu, et al., Stretchable and highly sensitive graphene
onpolymer strain sensors, Scientific Reports, 2 (2012).
C [210] Y. Ma, N. Liu, L. Li, X. Hu, Z. Zou, J. Wang, et al., A highly flexible and sensitive piezoresistive S sensor based on MXene with greatly changed interlayer distances, Nature Communications, 8 (2017)
article number 1207.
U [211] DH. Kim, N. Lu, R. Ma, YS. Kim, RH. Kim, S. Wang, et al., Epidermal Electronics, Science, N 333:6044 (2011) 838843. A [212] W.R. Loewenstein and R. Skalak, Mechanical transmission in a Pacinian corpuscle. An analysis and
a theory, The Journal of Physiology, 182:2 (1966) 346378.
M [213] L.A. Jones A.M. Smith, Tactile sensory system: Encoding from the periphery to the cortex, Wiley
Interdisciplinary Reviews: Systems Biology and Medicine, 6:3 (2014) 279287.
D [214] A.P. Chandrakasan, N. Verma, D.C. Daly, Ultralow-Power Electronics for Biomedical Applications, ACCEPTE Annual Review of Biomedical Engineering, 10 (2008) 247274.
48
Antonino S. Fiorillo graduated in Electronic Engineering in 1984 and earned a Ph.D. in Electronic Devices and Technologies in 1988, both at the University of Pisa, Italy. From 1984 to 1991 he was a research scientist at the “Centro E. Piaggio” School of Engineering, at the same university, where he was involved in the development of proximity and tactile sensors based on ferroelectric polymer technology for robotic applications. He had been an assistant professor at the University of Salerno and the University of Sannio, from 1991 to 2003, when he was awarded the position of associate professor in electronics and sensors at the University of Magna Græcia in Catanzaro, Italy, where he is presently working. He was visiting scientist from 1987 to 1997, and then visiting professor from 1997 to 2002 at the “Center of Sensor Technologies” of the University of Pennsylvania, PA. His primary research interests are in the area of discrete and silicon integrated sensors based on ferroelectric and conducting polymers for application in the fields of robotics and medicine, besides electrical brain stimulation, and the interfacing of electronic and biological systems with
T nanoporous materials on silicon. IP Costantino Davide Critello completed his Bachelors and Masters degrees in Biomedical Engineering at
the University Magna Graecia of Catanzaro (Italy) in 2007 and 2011, respectively. He also received from the
R same University a 2nd level postgraduate specialization in Biomedical Electronics in 2013, and his Doctoral
degree in Biomedical Engineering in 2016.
C He is currently working as post-doctoral researcher in the Department of Health Sciences at the University S Magna Graecia of Catanzaro (Italy). His main research interests focus on piezoelectric sensors, ultrasound,
cavitation generation, and development and characterization of soft materials.
U Salvatore A. Pullano received the B.S. and M.S. degrees in electronic engineering from the University of N Calabria, Italy, and the Ph.D. in Biomedical Engineering and Computer Science from the University Magna
Græcia of Catanzaro, Italy. Currently, he is a Post-Doctoral Fellow in the Department of Health Sciences at
A the University Magna Græcia of Catanzaro, Italy and Adjunct Assistant Professor at the University of
Tennessee-Knoxville. His research interests include the design of pyroelectric and piezoelectric sensors,
M electronic systems and nanoporous materials for biomedical applications. ACCEPTED
49
Figure Captions
Fig. 1. Literature involving the use of the piezoresistive effect from 1960-2018. Source: Scopus.
Fig. 2. a) Piezoresistive bar to which traction is applied. b) Cross-section of a planar strain gauge to which an electrical potential V is applied along the width W, while traction is
T applied along the length l, orthogonal to the page (transverse piezoresistive effect). IP Fig. 3. a) Energy plot of free particle (dotted line) compared to that of a particle
(continuous line) which moves in an ordered structure of potential wells; when the energy
R E increases the two curves tend to partially overlap in the allowed bands (not shown in C Fig.). b) Second derivative of energy versus the wave number. S Fig. 4. Minimum energy surfaces for a) germanium, b) gallium arsenide, and c) silicon in U unstrained state (solid lines) and by applying external stress (dashed lines). The mobility N T, and L represent the components, perpendicular and longitudinal, respect to the A principal axis. M Fig. 5. Conduction band and valence band in silicon along [111] and [100] k-directions
[38].
D Fig. 6. a) Conductive particles dispersed in an insulating matrix. b) The origin of an E electrical conduction path at the percolation threshold b). PT Fig. 7. Conductive rubber tactile sensor. E Fig. 8. Various strain gauge configurations. C Fig. 9. Two different configuration of force/displacement transducer. ACFig. 10. Etching process steps for Si-cantilever production (only one electrode is shown).
Fig. 11. Cruciform pressure sensor etched on a silicon membrane (not shown).
Fig. 12. Indirect flow measurement.
50
Fig. 13. Torque sensor in which two strain gauges along a diagonal experience a traction, while the other two (along the other diagonal) experience a compression. Fig. 14. Acceleration sensor. Fig. 15. Wheatstone Bridge connected to a differential dc amplifier.
T Fig. 16. Instrumentation or differential buffer amplifier. P Fig. 17. Half Bridge connected to a current-to-voltage converter. RI Fig. 18. Double current-to-voltage converter [3]. C Fig. 19. On-silicon integrated Wheatstone bridge cascaded with a CMOS differential S amplifier. ANU Fig. 20. Timeline of the main steps in the development of piezoresistive sensor technology.
M ACCEPTED
Figures
51
Figure 1
ANUSCRIPT
M
ACCEPTED
52
Figure 2
ANUSCRIPT
M
ACCEPTED
53
ANUSCRIPT M ACCEPTED Figure 3
54
ANUSCRIPT M ACCEPTED Figure 4
55
ANUSCRIPT M ACCEPTED Figure 5
56
Figure 6
ANUSCRIPT
M
ACCEPTED
57
Figure 7
ANUSCRIPT
M
ACCEPTED
58
Figure 8
ANUSCRIPT
M
ACCEPTED
59
Figure 9
ANUSCRIPT
M
ACCEPTED
60
Figure 10
ANUSCRIPT
M
ACCEPTED
61
Figure 11
ANUSCRIPT
M
ACCEPTED
62
ANUSCRIPT M ACCEPTED Figure 12
63
Figure 13
ANUSCRIPT
M
ACCEPTED
64
Figure 14
ANUSCRIPT
M
ACCEPTED
65
Figure 15
ANUSCRIPT
M
ACCEPTED
66
Figure 16
ANUSCRIPT
M
ACCEPTED
67
Figure 17
ANUSCRIPT
M
ACCEPTED
68
Figure 18
ANUSCRIPT
M
ACCEPTED
69
Figure 19
ANUSCRIPT
M
ACCEPTED
70
Figure 20
ANUSCRIPT
M
ACCEPTED
71
Table 1 Resistivity and longitudinal gauge factors of the most common metals used for piezoresistive sensors.
Material
Resistivity ( 20 °C) [106 ·cm]
GFl
Ref.
Aluminum
2.650
3.1
[33, 30]
Copper
1.678
2.9
[33, 30]
Gold
2.214
4.48
[33, 35]
Iron Nichrome V Nickel
T Platinum
Silver (printed)
9.61 100 6.93 10.5 1.587
4.2 2.0 12.2 4.8 3.350.13
[33, 32] [34, 32] [31, 32] [33, 32] [33, 29]
RIP Table 2
Longitudinal gauge factors of the most common semiconductor materials.
C Material US pSi
nSi
N pGe
nGe
A nGaAs
GFl
Silicon
[111] 175 135 105 155 8.9
[110] 120 61.4 65 105 6.7
[100] 8.6 133 10.9 5.3 3.2
Ref.
[42, 51, 52] [42, 51, 52] [30, 42] [30, 42] [30]
Polysilicon
M random nSi
82.1
[52]
random pSi 87.5
[52]
Silicon Carbide
D n6HSiC
29.4
[40]
p6HSiC 27
[40]
TE Table 3
Resistivity of a few representative polymer conductive composites.
PMaterial ECarbon Black/Silicone
SWNT/PMMA
CMWCNT/PDMS Graphene/Polystyrene
C Expanded Graphite/PMMA Expanded Graphite/Epoxy
A Polyethylene terephthalate/graphene
Resistivity
[Ω·cm]
105 103 105 104 105 106 ~103
Wt %
5 2 5 2 1 3 0.47
Ref.
[82] [89] [84] [88] [90] [90] [92]
72
Table 4 Tactile sensor parameters.
Ref.
Articulator design
Single/multi finger, handlike
[120, 123]
Force
Range , direction (e.g. normal, tangential)
[124]
Resolution
Temporal (typ. 1 ms), spatial (15 mm)
[123]
Static characteristics Dynamic characteristics
T Material properties
Linearity, Hysteresis (<5 %) Dynamic range (1000:1), bandwidth (100 Hz or more) Flexibility, compliance, conductive mechanisms, thermal stability
[123] [122, 124]
[123, 125]
RIP Table 5
Displacement piezoresistive sensors.
C Type Material
B
Silicon
S B
SWNT
C
n+ Al0.4Ga0.6As
U C
CrNi
AN B: Beam, C: Cantilever.
Displacement 411 mm 30/40 nm 10 pm Hz1/2
200 m
Force 1 N 50 nN
74 mV/m
Size 11 x 11 mm2 200 nm2
400 x 160 m2 24 x 24 mm2
Ref. [129] [135] [136] [137]
Table 6 Flow Sensor parameters.
Size
M [µm2]
Flow Range [m/s]
4000 x 400
4000 x 1200
D 4000 x 2000
20 x 90
E 400 x 1100
1500 x 400
545 545 545 065 0.20.95 017
ACCEPT A: Air, W: Water.
Material
Pt Pt Pt pSiNW pSi Elastomer
Sensitivity [Ω·m1·s1]
0.0134 (A) 0.0227 (A) 0.0284 (A) 198 (A) 4573.9 (W) 66 (A)
Response time [s]
1.38 0.99 0.53
Ref.
[155] [155] [155] [156] [151] [157]
73
Table 7 Wheatstone bridge configurations.
T Configuration P 1 varying element RI 2 varying elements C 4 varying elements
Elements
Output Voltage
R4=R+R R1, R2, R3=R
V/4·(R/(R+R/2))
R1=R4=R+R R2, R3=R
V/2·(R/(R+R/2))
R2=RR; R3=R
R4=R+R
R1, V/2·(R/R)
R1= R4=R+R R2=R3=RR
V·(R/R)
NUS Table 8
CMOS readout interface for piezoresistive sensors.
A Type
Pressure
M Pressure
Sensitivity 8.9 mV/psi 4.8 mV/psi
Power 3 W 300 W
Dimension 4 x 4 mm2 4 x 4 mm2
Process 0.35 m 0.35 m
Ref. [187] [188]
Pressure Pressure
ACCEPTED Pressure
159.5 mV/V/bar 18µV/ V/mbar 450 µV/ V/mbar
200 W
1x1.2 mm2 0.2 x 0.2 mm2
0.13 μm 0.35 μm
[189] [190] [191]
Table 9 Summary Table Material Metal alloy
Cr/Au
Design Circular Ultrathin film Thick film Cruciform cantilever
NiCr
Beam
SCRIPT Application
Tactile Sensors for
U Hand Exoskeletons
Sensitivity 0.764.18 s/bar
Other characteristics Hysteresis 12108 ns
Tactile force, shear stress, fluid
N flow
0.03 V/μN
Resolution 1 μN
MA Tactile sensor (force and curvature)
curvature, force and deflection 40 ppm·m, 340 ppm/nN and 230 ppm/m
Zr55Cu30Ni5Al10 metallic glass
Thinfilm layer Tactile sensor
ED Graphene
Cylindrical film
thick
Accelerometer
T PDMS/Graphene Nano P platelets
Cylindrical film
thick
Pressure sensor
E Polyethylenimine/Grap ACC hene Oxide
Ultrathin film
Strain sensor
CNT/PDMS
Double spiral
Tactile sensor
2.6 mV/g 0.23 kPa1
GF 2.86 Electric conductivity 5 103 Scm1
Bandwidth: 20300 Hz
Max Pressure: 70 kPa
GF 754 (ɛ=5 %) Resolution 0.1 % Maximum strain up to 50 % Response time: 0.6 s
Strain: up to 60 % High sensitivity up to 1 N
SWCNT/PDMS
Thin film
Strain sensor
Measurable strain up to 280 %
74
Note Commercially available FSR Optically transparent Threeaxis force sensor
Ref [7]
[113]
eskin on substrate
flexible
[114]
Flexible substrate Light transmittances from 0.2 % to 54 % High time stability Use as accelerometer as well as microphone PDMS foam coated with conductive microplatelets
[115] [70] [72]
Detection of motion of human knuckles
[73]
Sensitivity can be
enhanced
by
controlling
the
content of CNT and
[77]
porosity of CNT
PDMS
Humanmotion detection
[78]
Carbon Black/silicone Thick film
SOI
Diaphragm
Pressure sensor Pressure Sensor
ANUSCRIPT 71 mV/bar
Durability: 10,000 strain cycles Linear up to 150 % strain GF: 0.82 Critical Pressure of 12 MPa GF of about 35 at low strain Pressure range: 010 bar Maximum nonlinearity of
M
0.2 % Pressure range: 030 bar Linearity: <0.3 % full
Polysilicon
ACCEPTED SiNWs
Diaphragm Cantilever
Pressure sensor Flow sensor
3.353.74 mV/bar 198 /m/s
scale Hysteresis: <0.1 % full scale Linearity: <0.1 % Power consumption: 1 W
Application electronic skin
75
in [82] [141] [145] [156]