Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
Paul L. Stanwix1, Michael E. Tobar1,† Peter Wolf2,3, Mohamad Susli1, Clayton
R. Locke1, Eugene N. Ivanov1, John Winterflood1, and Frank van Kann1 1University of Western Australia, School of Physics M013, 35 Stirling Hwy., Crawley 6009 WA, Australia
2SYRTE, Observatoire de Paris, 61 Av. de lObservatoire, 75014 Paris, France 3Bureau International des Poids et Mesures, Pavillon de Breteuil, 92312 S`evres Cedex, France
(Dated: July 20, 2021)
We present the first results from a rotating Michelson-Morley experiment that uses two orthogo-
nally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near
10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of
the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the
Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously
unmeasured κ˜ZeZ component of 2.1(5.7) × 1014, and set more stringent bounds by up to a factor
of 7 on seven other components. In the RMS a more stringent bound of 0.9(2.0) × 1010 on the
isotropy
parameter,
PM M
=δ−β+
1 2
is
set,
which
is
more
than
a
factor
of
7
improvement.
PACS numbers: 03.30.+p, 06.30.Ft, 12.60.-i, 11.30.Cp, 84.40.-x
arXiv:hep-ph/0506074v3 21 Jul 2005
The Einstein Equivalence Principle (EEP) is a founding principle of relativity [1]. One of the constituent elements of EEP is Local Lorentz Invariance (LLI), which postulates that the outcome of a local experiment is independent of the velocity and orientation of the apparatus. The central importance of this postulate has motivated tremendous work to experimentally test LLI. Also, a number of unification theories suggest a violation of LLI at some level. However, to test for violations it is necessary to have an alternative theory to allow interpretation of experiments [1], and many have been developed [2, 3, 4, 5, 6, 7]. The kinematical Roberson-MansouriSexl (RMS) [2, 3] framework postulates a simple parameterization of the Lorentz transformations with experiments setting limits on the deviation of those parameters from their values in special relativity (SR). Because of their simplicity they have been widely used to interpret many experiments [8, 9, 10, 11]. More recently, a general Lorentz violating extension of the standard model of particle physics (SME) has been developed [6] whose Lagrangian includes all parameterized Lorentz violating terms that can be formed from known fields.
This work presents first results of a rotating lab experiment using cryogenic microwave oscillators. Previous non-rotating experiments [10, 12, 13] relied on the earths rotation to modulate a Lorentz violating effect. This is not optimal for two reasons. Firstly, the sensitivity is proportional to the noise of the oscillators at the modulation frequency, typically best for periods between 10 and 100 seconds. Secondly, the sensitivity is proportional to the square root of the number of periods of the modulation signal, therefore taking a relatively long time to acquire sufficient data. Thus, by rotating the experiment the data integration rate is increased and the relevant signals are translated to the optimal operating regime [14].
Our experiment consists of two cylindrical sapphire resonators of 3 cm diameter and height supported by spindles within superconducting niobium cavities [15], and are oriented with their cylindrical axes orthogonal to each other in the horizontal plane. Whispering gallery modes [16] are excited near 10 GHz, with a difference frequency of 226 kHz. The frequencies are stabilized using Pound locking, and amplitude variations are suppressed using an additional control circuit. A detailed description of such oscillators can be found in [17, 18]. The resonators are mounted in a common copper block, which provides common mode rejection of temperature fluctuations. The structure is in turn mounted inside two successive stainless steel vacuum cylinders from a copper post, which provides the thermal connection between the cavities and the liquid helium bath. A foil heater and carbon-glass temperature sensor attached to the copper post controls the temperature set point to 6 K with mK stability.
A schematic of the rotation system is shown in Fig.1. The cryogenic dewar along with the room temperature oscillator and control electronics is suspended within a ring bearing. A multiple ”V” shaped suspension made from elastic cord avoids high Q-factor pendulum modes by ensuring that the cord has to stretch and shrink (providing damping) for horizontal and vertical motion. The rotation system is driven by a microprocessor controlled stepper motor. A commercial 18 conductor slip ring connector, with a hollow through bore, transfers power and various signals to and from the rotating experiment. A mercury based rotating coaxial connector transmits the difference frequency to a stationary frequency counter referenced to an Oscilloquartz oscillator. The data acquisition system logs the difference frequency as a function of orientation, as well as monitoring systematic effects including the temperature of the resonators, liquid helium
2
FIG. 1: Schematic of the cryogenic dewar, mounted in the rotation table. Inside the dewar a schematic of the two orthogonally orientated resonators is shown, along with the Poynting vectors of propagation S1 and S2.
FIG. 2: Square Root Allan Variance fractional frequency instability measurement of the difference frequency when rotating (crosses) and stationary (circles). The hump at short integration times is due to systematic effects associated with the rotation of the experiment, with a period of 18 seconds. Above 18 seconds the instability is the same as when the experiment is stationary.
bath level, ambient room temperature, oscillator control signals, tilt, and helium return line pressure.
Inside the sapphire crystals standing waves are set up with the dominant electric and magnetic fields in the axial and radial directions respectively, corresponding to a Poynting vector around the circumference. The experi-
mental observable is the difference frequency, and to test
for Lorentz violations the perturbation of the observable
with respect to an alternative test theory must be de-
rived. For example, in the photon sector of the SME this
may be calculated to first order as the integral over the
non-perturbed fields (Eq. (34) of [7]), and expressed in
terms of 19 independent variables (discussed in more de-
tail later). The change in orientation of the fields due
to the lab rotation and Earths orbital and sidereal mo-
tion induces a time varying modulation of the difference
frequency, which is searched for in the experiment. Al-
ternatively, with respect to the RMS framework, we an-
alyze the change in resonator frequency as a function of
the Poynting vector direction with respect to the veloc-
ity of the lab through the cosmic microwave background
(CMB). The RMS parameterizes a possible Lorentz vi-
olation by a deviation of the parameters (α, β, δ) from
their
SR
values
(
1 2
,
1 2
,
0).
Thus,
a
complete
verification
of LLI in the RMS framework [2, 3] requires a test of (i)
the
isotropy
of
the
speed
of
light
(PM M
=
δ
−β
+
1 2
),
a
Michelson-Morley (MM) experiment [19], (ii) the boost
dependence of the speed of light (PKT = β α 1), a
Kennedy-Thorndike (KT) experiment [20] and (iii) the
time
dilation
parameter
(PIS
=
α
+
1 2
),
an
Ives-Stillwell
(IS) experiment [21, 22]. Because our experiment com-
pares two cavities it is only sensitive to PMM . Fig.2 shows typical fractional frequency instability of
the 226 kHz difference with respect to 10 GHz, and com-
pares the instability when rotating and stationary. A
minimum of 1.6 × 1014 is recorded at 40s. Rotation in-
duced systematic effects degrade the stability up to 18s
due to signals at the rotation frequency of 0.056Hz and
its harmonics. We have determined that tilt variations
dominate the systematic by measuring the magnitude of
the fractional frequency dependence on tilt and the varia-
tion in tilt at twice the rotation frequency, 2ωR(0.11Hz),
as the experiment rotates. We minimize the effect of tilt
by manually setting the rotation bearing until our tilt
sensor reads a minimum at 2ωR. The latter data sets
were up to an order of magnitude reduced in amplitude
as we became more experienced at this process. The re-
maining systematic signal is due to the residual tilt varia-
tions, which could be further annulled with an automatic
tilt control system. It is still possible to be sensitive to
Lorentz violations in the presence of these systematics by
measuring the sidereal, ω⊕ and semi-sidereal, 2ω⊕ side-
bands about 2ωR, as was done in [8]. The amplitude and
phase of a Lorentz violating signal is determined by fit-
ting the parameters of Eq.1 to the data, with the phase
of the fit adjusted according to the test theory used.
ν0 = A+Bt+ ν0
i
Cicos(ωit+ϕi)+Sisin(ωit+ϕi) (1)
Here ν0 is the average unperturbed frequency of the two sapphire resonators, and ∆ν0 is the perturbation of the 226 kHz difference frequency, A and B determine the
3
FIG. 3: Spectrum of amplitudes Ci2 + Si2 calculated using WLS, showing systematic leakage about 2ωR for 2 data sets, data set 1 (3.6 days, circles), data set 5 (6.1 days, squares) and the combined data (18 days spanning 3 months, solid triangles). Here ω⊕ is the sidereal frequency (11.6µHz). By comparing a variety of data sets we have seen that leakage is reduced in longer data sets with lower systematics. The insets show the typical amplitude away from the systematic, which have statistical uncetainties of order 1016.
frequency offset and drift, and Ci and Si are the amplitudes of a cosine and sine at frequency ωi respectively. In the final analysis we fit 5 frequencies to the data, ωi = (2ωR, 2ωR±ω⊕, 2ωR±2ω⊕), as well as the frequency offset and drift. The correlation coefficients between the fitted parameters are all between 102 to 105. Since the residuals exhibit a significantly non-white behavior, the optimal regression method is weighted least squares (WLS) [13]. WLS involves pre-multiplying both the experimental data and the model matrix by a whitening matrix determined by the noise type of the residuals of an ordinary least squares analysis.
We have acquired 5 sets of data over a period of 3 months beginning December 2004, totaling 18 days. The length of the sets (in days) and size of the systematic are (3.6, 2.3 × 1014), (2.4, 2.1 × 1014), (1.9, 2.6 × 1014), (4.7, 1.4 × 1015), and (6.1, 8.8 × 1015) respectively. We have observed leakage of the systematic into the neighboring side bands due to aliasing when the data set is not long enough or the systematic is too large. Fig.3 shows the total amplitude resulting from a WLS fit to 2 of the data sets over a range of frequencies about 2ωR. It is evident that the systematic of data set 1 at 2ωR is affecting the fitted amplitude of the sidereal sidebands 2ωR ± ω⊕ due to its relatively short length and large systematics. By analyzing all five data sets simultaneously using WLS the effective length of the data is increased, reducing the width of the systematic sufficiently as to not contribute significantly to the sidereal and semi-sidereal sidebands.
In the photon sector of the SME [7], Lorentz violating terms are parameterized by 19 independent components, which are in general grouped into three traceless and
symmetric 3 × 3 matrices (κ˜e+, κ˜o, and κ˜e), one antisymmetric matrix(κ˜o+) and one additional scalar, which all vanish when LLI is satisfied. To derive the expected
signal in the SME we use the method of [7, 11] to calculate the frequency of each resonator in the SME and in
the resonator frame. We then transform to the standard
celestial frame used in the SME [7] taking into account the rotation in the laboratory frame in a similar way
to [23]. The resulting relation between the parameters
of the SME and the Ci and Si coefficients are given in Tab.I which, for short data sets, were calculated using
the leading order expansion at the annual phase position of the data. The 10 independent components of κ˜e+ and κ˜o have been constrained by astronomical measurements to < 2 × 1032 [7, 25]. Seven components of κ˜e and κ˜o+ have been constrained in optical and microwave cavity experiments [10, 13] at the 1015 and 1011 level
respectively, while the scalar κ˜tr component recently had an upper limit set of < 104 [23]. The remaining κ˜ZeZ component could not be previously constrained in non-
rotating experiments [10, 13]. In contrast, our rotating experiment is sensitive to
κ˜ZeZ. However, it appears only at 2ωR, which is dominated by systematic effects. From our combined analysis of all data sets, and using the relation to κ˜ZeZ given in Tab.I, we determine a value for κ˜ZeZ of 4.1(0.5) × 1015. However, since we do not know if the systematic has can-
celed a Lorentz violating signal at 2ωR, we cannot reasonably claim this as an upper limit. Since we have five individual data sets, a limit can be set by treating the
C2ωR coefficient as a statistic. The phase of the systematic depends on the initial experimental conditions, and
is random across the data sets. Thus, we have five values of C2ωR , ({4.2, 11.4, 21.4, 1.3, 8.1} in 1015). If we take the mean of these coefficients, the systematic
signal will cancel if its phase is random, but the possible
Lorentz violating signal (with constant phase) will not. Thus a limit can be set by taking the mean and stan-
dard deviation of the five coefficient of C2ωR . This gives a more conservative bound of 2.1(5.7) × 1014, which in-
cludes zero. Our experiment is also sensitive to all other
seven components of κ˜e and κ˜o+ (see Tab.I) and improves present limits by up to a factor of 7, as shown in
Tab.II.
In the RMS frame-work, a frequency shift due to a putative Lorentz violation is given by Eq.2 [9, 11],
ν0 ν0
=
PM M 2πc2
2
v.θˆ1 dϕ1
2
v.θˆ2 dϕ2 (2)
Where v is the velocity of the preferred frame wrt the CMB, θˆj is the unit vector in the direction of the azimuthal angle (direction of propagation) of each resonator (labeled by subscripts 1 and 2), and ϕ is the azimuthal variable of integration in the cylindrical coordinates of each resonator. Perturbations due to Lorentz violations occur at the same five frequencies as the SME,
4
TABLE I: Coefficients Ci and Si in (1) for the five frequencies of interest and their relation to the components of the SME parameters κ˜e and κ˜o+, derived using a short data set approximation including terms up to first order in orbital velocity, where Φ0 is the phase of the orbit since the vernal equinox (see [24] for details of the calculation). Note that for short data sets the upper and lower sidereal sidebands are redundant, which reduces the number of independent measurements to 5. To lift the redundancy, more than a year of data is required so annual offsets may be de-correlated from the twice rotational and sidereal sidebands listed.
ωi 2ωR 2ωR + ω⊕
2ωR + 2ω⊕
2ωR ω⊕ 2ωR 2ω⊕
Ci
0.21κ˜ZeZ 2.5 × 105 sin Φ0κ˜X o+Y 1.0 × 105 cos Φ0κ˜Yo+Z
0.27 κ˜X eZ 2.1 × 105 cos Φ0κ˜X o+Z +2.3 × 105 sin Φ0κ˜Yo+Z 0.11(κ˜X eX κ˜YeY )
0.31C2ωR +ω⊕ 9.4 × 102C2ωR+2ω⊕
Si
cos Φ0 2.3 × 10˜X o+Y 1.0 × 10˜X o+Z
0.27κ˜YeZ 2.3 × 105 sin Φ0κ˜X o+Z 2.1 × 105 cos Φ0κ˜Yo+Z 0.23 κ˜X eY
0.31S2ωR +ω⊕ 9.4 × 102S2ωR+2ω⊕
TABLE II: Results for the SME Lorentz violation parameters,
assuming no cancelation between the isotropy terms κ˜e (in 1015) and first order boost terms κ˜o+ (in 1011) [12].
κ˜X eY
κ˜X eZ
κ˜YeZ
˜X eX κ˜YeY )
this work -0.63(0.43) 0.19(0.37) -0.45(0.37) -1.3(0.9)
from [13] -5.7(2.3) -3.2(1.3) -0.5(1.3) -3.2(4.6)
this work from [13]
κ˜ZeZ 21(57)
κ˜X o+Y
κ˜X o+Z
0.20(0.21) -0.91(0.46)
-1.8(1.5) -1.4(2.3)
κ˜Yo+Z 0.44(0.46)
2.7(2.2)
improve these results, tilt and environmental controls will be implemented to reduce systematic effects. To remove the assumption that κ˜o+ and κ˜e do not cancel each other, data integration will continue for more than a year. Note added: Two other concurrent experiments have also set some similar limits [26, 27].
This work was funded by the Australian Research Council.
TABLE III: Dominant coefficients in the RMS, using a short
data set approximation calculated from Eq.2. The measured values of PMM (in 1010) are shown together with the sta-
tistical uncertainties in the bracket. From this data the mea-
sured and statistical uncertainty of PMM is determined to be 0.9(2.0) × 1010, which represents more than a factor of 7 improvement over previous results 2.2(1.5) × 109[10].
ωi
C ui
PM M
2ωR + ω⊕ [1.13 × 107 3.01 × 108 cos Φ0 2.1(7.2)
+8.83 × 109 sin Φ0]PMM
2ωR ω⊕ [3.51 × 108 + 9.31 × 109 cos Φ0 62.4(23.3)
2.73 × 109 sin Φ0]PMM
2ωR + 2ω⊕ [4.56 × 107 1.39 × 108 cos Φ0 1.3(2.1)
7.08 × 108 sin Φ0]PMM
2ωR 2ω⊕ [4.37 × 108 1.34 × 109 cos Φ0 7.5(22.1)
6.78 × 109 sin Φ0]PMM
but for the RMS analysis we do not consider the 2ωR frequency due to the large systematic, as we only need to put a limit on one parameter. The dominant coefficients are due to only the cosine terms with respect to the CMB right ascension, Cui, which are shown in Tab.III.
In conclusion, we set bounds on 7 components of the SME photon sector (Tab.II) and PMM (Tab.III) of the RMS framework, which are up to a factor of 7 more stringent than those obtained from previous experiments. We have also set an upper limit [2.1(5.7) × 1014] on the previously unmeasured SME component κ˜ZeZ . To further
Electronic address: pstanwix@physics.uwa.edu.au † Electronic address: mike@physics.uwa.edu.au [1] Will C. M., Theory and Experiment in Gravitational
Physics, revised edition (Cambridge University Press, Cambridge, 1993). [2] Robertson H.P., Rev. Mod. Phys. 21, 378 (1949). [3] Mansouri R., Sexl R.U., Gen. Rel. Grav. 8, 497, (1977). [4] Lightman A.P., Lee D.L., Phys. Rev. D8, 364, (1973). [5] Ni W.-T., Phys. Rev. Lett. 38, 301, (1977). [6] Colladay D., Kostelecky´ V.A., Phys.Rev.D55, 6760, (1997); Colladay D., Kostelecky´ V.A., Phys.Rev.D58, 116002, (1998) [7] Kostelecky´ V.A.,Mewes M.,Phys.Rev.D66,056005,(2002). [8] Brillet A., Hall J., Phys. Rev. Lett. 42, 549, (1979). [9] Wolf P. et al., Phys. Rev. Lett. 90, 060402, (2003). [10] Mu¨ller H. et al., Phys. Rev. Lett. 91, 020401, (2003). [11] Wolf P., et al., Gen. Rel. and Grav., 36, 2351, (2004). [12] Lipa J.A. et al. Phys. Rev. Lett. 90, 060403, (2003). [13] Wolf P, et al., Phys. Rev. D70, 051902(R), (2004). [14] Tobar M.E. et al., Phys. Lett. A 300, 33, (2002). [15] Giles A.J. et. al., Physica B 165, 145, (1990). [16] Tobar M.E., Mann A.G., IEEE Trans. Microw. Theory Tech. 39, 2077, (1991). [17] Mann A.G., Topics in Appl. Phys. 79, 37, (2001) [18] Hartnett J.G., Tobar M.E., Topics in Appl. Phys. 79, 67, (2001) [19] Michelson A.A. and Morley E.W., Am. J. Sci. 34, 333 (1887). [20] Kennedy R.J. and Thorndike E.M., Phys. Rev. B42, 400 (1932). [21] Ives H.E. and Stilwell G.R., J. Opt. Soc. Am. 28, 215 (1938).
5
[22] Saathoff G., et al., Phys. Rev. Lett 91, 190403 (2003). [23] Tobar M.E. et. al., Phys.Rev.D71,025004,(2005). [24] Tobar M.E. et. al., to be published in Springer Lecture
Notes in Physics 2005: ArXiv: hep-ph/0506200. [25] Kostelecky´ V.A., and Mewes M., Phys. Rev. Lett. 87,
251304 (2001). [26] Antonini, M. Okhapkin, E. G¨oklu¨ and S. Schiller, Phys.
Rev. A 71, 050101R 2005. [27] Herrmann S. et. al., (to be published).